Nuvo NV-E6MS, NV-E6XS manual Installing and Terminating Cables, Pin #

Page 8

INSTALLING YOUR E SERIES

SYSTEM

I. Installing and Terminating Cables

The basic installation requires two different types of cables. The keypads communicate with the E6M amplifier through Cat-5 data cable (4 twisted-pair). This cable is terminated at both ends with RJ45 connectors. The wiring scheme is standard EIA/TIA 568A, which is a standard for computer networking (see Fig. 1). These cables are routed in walls, crawl spaces, or attics, and go from the location of each keypad to the location of the E-Z Port hub.

It is important to use a high-quality crimptool to assure the best possible connections. Testing each termination with a Cat-5 cable tester is crucial before installing the keypads. Improperly wired cable can damage the E6M amplifier or the keypads.

The second type of cable used is AWG 16-2 or 16-4 speaker cable (AWG 14-gage can be used as well). These are routed in the walls, crawl spaces, or attics, and go from the location of a speaker to the location of the E6M amplifier. These cables are terminated at the E6M using the supplied 4-pin terminal block connectors.

Using more than one pair of 8-ohm speakers is not recommended. Doing so could overheat and damage the amplifier and will void the warranty.

When routing the Cat-5 and speaker cables, be careful to avoid running them in parallel with any other cables, such as AC, low voltage lighting, or home automation.

Important Note: This unit generates large amounts of heat so please remember to allow for adequate ventilation. The top clearance must be at least 1 inch (25mm).

Fig. 1: 568A Cat-5 wiring scheme

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pair

2

 

 

Pair 1

 

Pair 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pair 3

After stripping the insulation off a portion of the Cat-5, untwist the wires and fan them out in the correct color order from left to right. Each of the RJ-45 connectors is terminated in the following pin order again from left to right.

Pin #

1.Green Stripe

2.Green

3.Orange Stripe

4.Blue

5.Blue Stripe

6.Orange

7.Brown Stripe

8.Brown

Note: Colors listed as “Stripe” are a white wire with a colored stripe. In other words, Orange Stripe is a white wire with orange stripes.

Page 6

Image 8
Contents Series NV-E6MS/NV-E6XS Nuvo Technologies Inc NV-E6MS Main Audio Distribution System Description NV-E6XS Expander Audio Distribution System DescriptionSeries Amplifier Front Series Amplifier Back Panel 3 4 5Series Keypad Nuvo RC1 Remote Control IR EmitterInstalling and Terminating Cables Pin #Cat-5 cables from keypads II. Installing the E-Z Port HubIII. Connecting the E6M to the E-Z Port Connecting the IR Emitters IV. Attaching Source Equipment to the E6MVI. Connecting the E6M to the E6X VII. Installing the NV-EKP KeypadsE6M Amplifier NV-DI3 Datalink Cable NV-AI2 Audiolink CableVIII. Setting the NV-EKP DIP Switches DIP switches ZoneSwitches 5 & 6, Zone EQ Presets +4dB Boost At 100Hz At 10kHz +4dB Boost At 100Hz and 10kHz Flat ResponseUsing the Mute and Unit On Pins NV-RC1 Remote Learning RemoteXI. MPU Diagnostic LEDs MI1 is not supplied with the E6M or the E6X packages XII. Changing the Buttons on the NV-EKPXIII. NV-MI1 Mute Interface Troubleshooting Symptom Probable CauseNuvo NV-E6M Specifications WarrantyDelhi Pike, Cincinnati, OH USA