Carrier 50JS instruction manual AÐPhysical Data, BÐPhysical Data

Models: 50JS

1 28
Download 28 pages 58.47 Kb
Page 7
Image 7

Table 1AÐPhysical Data

UNIT SIZE

50JS018

 

50JS024

50JS030

 

50JS036

50JS042

 

50JS048

50JS060

NOMINAL CAPACITY (ton)

1-1/2

 

2

2-1/2

 

2-1/2

3-1/2

 

4

5

 

 

 

 

 

 

 

 

 

 

 

OPERATING WEIGHT (lb)

283

 

289

287

 

291

323

 

353

418

 

 

 

 

 

 

 

 

 

 

 

COMPRESSOR QUANTITY

 

 

 

 

 

1

 

 

 

 

TYPE

 

RECIPROCATING COMPRESSOR

 

 

SCROLL COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

 

 

 

 

 

R-22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT METERING DEVICE

 

 

 

 

 

Accurater ®

 

 

 

 

Refrigerant (R-22) Quantity (lb.)

5.6

 

5.2

5.8

 

7.1

7.6

 

7.8

8.6

 

 

 

 

 

 

 

 

 

 

 

ORIFICE ID (in.)

0.053

 

0.061

0.068

 

0.078

0.078

 

0.088

0.093

 

 

 

 

 

 

 

 

 

 

 

ORIFICE OD (in.)

0.040

 

0.049

2@0.042

 

2@0.046

2@0.052

 

2@0.057

2@0.061

OUTDOOR COIL

1....17

 

1....17

1....17

 

2....17

2....17

 

2....17

2....17

Rows...Fins/in.

 

 

 

10.2

 

12.0

12.0

 

10.3

10.3

 

11.6

11.6

Face Area (sq ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR FAN

2400

 

2400

2400

 

2800

2400

 

3300

3300

Nominal Airflow (CFM)

 

 

 

22

 

22

22

 

22

22

 

22

22

Diameter

 

 

 

1/8 (825)

 

1/8 (825)

1/8 (825)

 

1/4 (1100)

1/8 (825)

 

1/4 (1100)

1/4 (1100)

Motor HP (RPM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL

2....15

 

2....15

3....15

 

3....15

4....15

 

3....15

4....15

Rows...Fins/in.

 

 

 

3.7

 

3.7

3.7

 

3.7

3.7

 

4.7

4.7

Face Area (Sq Ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR BLOWER

700

 

800

1000

 

1200

1250

 

1600

2000

Nominal Airflow (CFM)

 

 

 

10x10

 

10x10

11x10

 

11x10

11x10

 

11x10

11x10

Size (in.)

 

 

 

1/8

 

1/4

1/4

 

1/2

3/4

 

3/4

1

Motor (HP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)

20x20x1

 

20x20x1

20x20x1

 

20x24x1

24x30x1

 

24x30x1

24x30x1

Throwaway

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1BÐPhysical Data

UNIT SIZE

50JX024

50JX030

50JX036

 

50JX042

50JX048

50JX060

 

 

 

 

 

 

 

 

NOMINAL CAPACITY (ton)

2

2 1/2

3

 

3-1/2

4

5

OPERATING WEIGHT (lb)

299

320

328

 

350

355

420

 

 

 

 

 

 

 

 

COMPRESSOR QUANTITY

 

 

 

1

 

 

 

 

 

 

 

 

 

TYPE

 

 

SCROLL COMPRESSOR

 

 

REFRIGERANT

 

 

 

R-22

 

 

 

 

 

 

 

 

 

REFRIGERANT METERING DEVICE

 

 

Accurater ®

 

 

 

 

 

 

 

 

 

 

Refrigerant (R-22) Quantity (lb.)

5.5

6.4

7.0

 

10.8

10.4

12.3

 

 

 

 

 

 

 

 

ORIFICE ID (in.)

0.065

0.073

0.076

 

0.080

0.088

0.0.93

ORIFICE OD (in.)

0.055

0.065

0.067

 

2@0.052

2@0.057

2@0.063

 

 

 

 

 

 

 

 

OUTDOOR COIL

1...17

2...17

2...17

 

2...17

2...17

2...17

Rows...Fins/in.

 

14.6

10.9

10.9

 

14.4

14.4

16.4

Face Area (sq ft)

 

 

 

 

 

 

 

 

OUTDOOR FAN

2350

2350

2800

 

2800

3300

3300

Nominal Airflow (CFM)

 

22

22

22

 

22

22

22

Diameter

 

1/8 (825)

1/8 (825)

1/4 (1100)

 

1/8 (825)

1/4 (1100)

1/4 (1100)

Motor HP (RPM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL

3...15

3...15

4...15

 

4..15

4...15

4...15

Rows...Fins/in.

 

3.7

3.7

3.7

 

4.7

4.7

5.7

Face Area (Sq Ft)

 

 

 

 

 

 

 

 

INDOOR BLOWER

800

1000

1200

 

1400

1600

2000

Nominal Airflow (CFM)

 

10x10

11x10

11x10

 

11x10

11x10

11x10

Size (in.)

 

1/4

1/4

1/2

 

3/4

3/4

1

Motor (HP)

 

 

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)

20x20x1

20x20x1

20x24x1

 

24x30x1

24x30x1

24x30x1

Throwaway

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Air filter pressure drop for non-standard filters must not exceed 0.08 in. wg.

Table 2AÐMinimum Airflow for Reliable Electric Heater Operation (Cfm)

SIZE

50JS018

50JS024

50JS030

50JS036

50JS042

50JS048

50JS060

AIRFLOW (CFM)

650

800

1000*

1200

1400

1600

2000

 

 

 

 

 

 

 

 

Table 2BÐMinimum Airflow for Reliable Electric Heater Operation (Cfm)

SIZE

50JX024

50JX030

50JX036

50JX042

50JX048

50JX060

 

 

 

 

 

 

 

AIRFLOW (CFM)

800

1000*

1200

1400

1600

2000

 

 

 

 

 

 

 

* The 030 size models must be run on medium or high speed when used in conjunction with 15 Kw electric heat accessory.

7

Page 7
Image 7
Carrier 50JS instruction manual AÐPhysical Data, BÐPhysical Data