MACHINE PREPARATION

Check to make sure that the pump intake strainer (Fig. 12), the drain pan strainer (Fig. 13), and the drain tube (Fig. 17) are in place and that both strainers are free of debris. The pump intake strainer must drop completely to the bottom of the sump. THE DRAIN AND STRAINERS MUST BE CLEAN AND FREE OF DEBRIS AT ALL TIMES.

PUMP INTAKE STRAINER

PL-40929-1

Fig. 12

DRAIN PAN

STRAINER

PL-40923-2

Fig. 13

Check the wash arms to make sure that they spin freely and that no nozzles are clogged.

To initially fill the machine, press the POWER switch On and press and hold the DRAIN/FILL switch on Fill for approximately ten seconds. Water level should be at the bottom of the ring on the drain tube (1.7 gallons) (Fig. 14). (Water to the top of the ring would be 1.9 gallons, and to the bottom of the overflow hole would be 2.3 gallons.) The overflow hole will automatically drain any excess water.

Check the chemical sight tubes (Fig. 15) before beginning dishwashing. Replenish any chemical supply containers that need to be replenished. If any chemical has been replenished, its delivery pump must be primed by pressing the corresponding prime switch — until the chemical reaches the end of the delivery tube.

OVERFLOW HOLE

WATER LEVEL (1.7 GALLONS)

CHEMICAL SIGHT TUBES

PL-40930-1

PL-40926-3

Fig. 14

Fig. 15

– 10 –

Image 10
Contents ONS Table of Contents General Location InstallationUnpacking LevelingInstallation Drawing Drain Connection Dish TablesPlumbing Connections Water Supply ConnectionChemical Supplies Electrical ConnectionPump Priming Cycle Timer Adjustment Operation Controls FigMachine Preparation Dishwashing Draining the DishwasherCleaning the Dishwasher Cleaning the Wash ArmsDOs and DONTs for Your NEW Hobart Warewasher Maintenance DelimingLubrication Troubleshooting