Frymaster FPD, SCFD manual Backup Operating Thermostat Optional

Page 16

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.6.2 Backup Operating Thermostat (Optional)

1.Fill the frypot to the lower OIL-LEVELline with oil. If solid shortening is used, it must be melted before starting the calibration procedure.

2.Light the pilot.

3.Set the temperature control knob to 350°F/177°C.

4.Let the burners cycle on and off automatically three times in order for the cooking oil temperature to become uniform. If necessary, stir to get all shortening in the bottom of the frypot melted.

5.Insert a thermometer or pyrometer probe into the oil, with the end near the fryer temperature- sensing probe.

NOTE: The temperature-sensing probe is mounted on the frypot tube.

6.When the burner starts for the fourth time, the thermometer/pyrometer reading should be within the range 335-360°F (168-182°C). If it is not, calibrate as follows:

a.Remove the thermostat knob by pulling straight out on the knob with a firm, steady pull. The temperature adjusting screw is located in the middle of the thermostat shaft.

b.Insert a small-bladed flat-tipped screwdriver into the adjusting screw. Turn the adjusting screw in ¼-turn increments to adjust the temperature. Turning the screw clockwise decreases the temperature; turning it counter-clockwise increases the temperature. DO NOT allow the thermostat shaft to turn while turning the adjusting screw.

c.Recheck the thermometer/pyrometer reading the next time the burner comes on.

d.Repeat steps 6.b. through 6.c. until the thermometer/pyrometer reading remains within the range 335-360°F (168-182°C) through several cycles. If calibration cannot be obtained for any reason, call a Factory Authorized Service Center for service.

e.Reinstall the thermostat knob.

7.Remove the thermometer or pyrometer.

1-11

Image 16
Contents Hour Service Hotline CFD, SCFD, FPDPage Computers FCC Table of Contents Finding Your WAY around the Dean Decathlon NON-CE Altitudes of 2000 feet or less Functional DescriptionCE only Altitudes of 2000 feet or less Pilot System Configuration Electronic Ignition ConfigurationControl Options Interface Boards Interface Board P/N Current Flow Through Interface Accessing Fryers for Servicing ThermostatsRestraints Cleaning the Gas Valve Vent Tube if applicable Adjusting Burner Manifold Gas PressureAdjusting the Pilot Flame Calibrating the ThermatronMain Pilot Trailing PilotBackup Operating Thermostat Optional Replacing Fryer Components Replacing the ComputerReplacing the Backup Thermostat if applicable Replacing the Temperature Probe Computer-equipped Fryers DrainsRemove burners to gain access to temperature probe Installing the New Temperature Probe Replacing the High-limit ThermostatRemove screws arrows securing high-limit to fryer Decathlon Series GAS Fryers Service Procedures Replacing Rocker Switches Switch GuardDecathlon Series GAS Fryers Service Procedures Replacing the Pilot Assembly Replacing the FrypotRemoving capping strip Removing flue cap Holding backup while unscrewing flare nut on oil-return line 19. a .5 drains Loosening burner bolts prior to burner removal Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Cutting frypot seal prior to frypot removal Troubleshooting and Problem Isolation Ignition FailureGas Valve Improper Burner FunctionDecathlon Series GAS Fryers Service Procedures Improper Temperature Control Improper Computer FunctionImproper Filtration Function Frypot Leakage Improper Basket Lift Function Bell-Crank Basket Lifts Improper Basket Lift Function Modular Basket Lifts Troubleshooting Guides Improper Basket Lift FunctionNot possible Wiring Diagrams Decathlon, Electronic Ignition, Current ConfigurationDecathlon, Dual Vat Thermatron Decathlon Series GAS Fryers Service Procedures Transformer Box Decathlon Interface Board Dean Oil Return Wiring OIL Return Micro Switch Filtration and Basket Lifts PBIOil Return, Left-hand, Normally Open Float Switch Basket Lift, with Timer CM4-S with Constant Pilot Chili’s Wiring Diagram Chili’s Wiring with SCF Filtration Decathlon Series GAS Fryers Parts List Decathlon Primary ComponentsDecathlon Series GAS Fryers Parts List Decathlon D20 Primary ComponentsDecathlon D50 Primary Components Decathlon 20 Primary Components826-1871 Decathlon D50 Primary Components 211-2787 Decathlon D60 Primary Components 826-2229Decathlon D60 Primary Components 106-1703SP Decathlon FPD65 Primary Components 823-3948SP212-4570 Decathlon D80 Primary Components 823-3494SPSee Optional Components, Section Decathlon D80 Primary Components Control Panel Options, Joiner Strips, and Accessories Control PanelsOptional Components and Controllers 16 17See Control Panel Options, Section Not illustrated Transformers & Component Boxes Multi-batteried Decathlons Part 823-3242To Drain 823-3221 Drain Valve ComponentsDecathlon Series GAS Fryers Parts List Flush Oil Drain Line Decathlon Series GAS Fryers Parts List Oil Return Manifold Components SCFD, CFD, & FPD65 Models ComponentOil Return and Oil Flush Components Oil Return and Oil Flush Components D & FPD65 ModelsOil Return and Oil Flush Components D & FPD65 Models Oil Suction Start Fitting2122 Microswitch Bracket Assembly, Oil Return Decathlon Series GAS Fryers Parts List UFF Filtration Components SCFD50 Series Fryers DescriptionUFF Filtration Components D60 and D80 Series Fryers UFF Filtration Components SCFD60 and FPD65 Series Fryers 106-1220SP Filter Pan ScfdUFF Filtration Components SCFD80 Series Fryers 823-3796 Suff Filtration Components CFD50 Series Fryers Suff Filtration Components D60 and D80 Series Fryers 823-3774Suff Filtration Components CFD60 and CFD80 Series Fryers 823-5420…2.10 Basket Lift Components D50, D60, and D80 Models Basket Lift Components D50, D60, and D80 Series Fryers Decathlon Series GAS Fryers Parts List Service Hotline