Frymaster FPD, SCFD manual Improper Temperature Control, Improper Computer Function

Page 39

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.8.3 Improper Temperature Control

Temperature control, including the melt cycle, is a function of several interrelated components, each of which must operate correctly. The principal component is the temperature probe. Depending upon the specific configuration of the fryer, other components may include the interface board, the computer/controller itself, and the ignition module. Improper temperature control problems can be categorized into melt cycle problems and failure to control at setpoint.

In fryers equipped with a Thermatron/optional backup operating-thermostat, the problem will be with the thermostats themselves. Possible causes are that the thermostats are out of calibration or defective. Refer to Section 1.6 for instructions on calibrating the thermostats.

In fryers equipped with computers, the problem may be with the temperature probe, the interface board, or the computer. Refer to the troubleshooting guides in this chapter.

1.8.4 Improper Computer Function

Sensitivity or "Stretch Time." Sensitivity—or stretch time—is a programmable feature that increases the cook time countdown based on variations in the oil temperature from the setpoint (e.g., when cold product is dropped into the oil, causing the oil temperature to drop). The sensitivity for each product button has 10 settings (0 through 9). A "0" sensitivity setting will disable the feature (no change in cooking time), while a nine will provide the highest sensitivity or the most change. The correct sensitivity for any product is based on the product type, its density, the setpoint temperature, and the customer’s own requirements.

Common Computer Complaints. Most problems concerning computers have to do with programming them. There are four common complaints. The complaints, their causes, and corrective actions are as follows:

1.Fryer constantly displays "". Cause: Setpoint incorrect or missing.

Corrective Action: Press 1 6 5 0, enter the correct setpoint using keypad, then press and then this to lock in the setpoint.

2.Temperature is displayed in Celsius.

Cause: Computer is programmed to display in Celsius.

Corrective Action: Press 1 6 5 8.

3.Temperature is constantly displayed.

Cause: Computer is programmed for constant temperature display.

Corrective Action: Press 1 6 5 L.

4.Computer times down too slowly or too quickly.

Cause: Computer is compensating for oil temperature via the sensitivity setting.

Corrective Action: Reprogram sensitivity setting for each product in accordance with programming instructions in the Compu-Fry Operation and Programming manual, P/N 819- 5865.

1-34

Image 39
Contents CFD, SCFD, FPD Hour Service HotlinePage Computers FCC Table of Contents Finding Your WAY around the Dean Decathlon Functional Description NON-CE Altitudes of 2000 feet or lessCE only Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options Interface Boards Interface Board P/N Current Flow Through Interface Thermostats Accessing Fryers for ServicingRestraints Adjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableTrailing Pilot Adjusting the Pilot FlameCalibrating the Thermatron Main PilotBackup Operating Thermostat Optional Replacing the Computer Replacing Fryer ComponentsReplacing the Backup Thermostat if applicable Drains Replacing the Temperature Probe Computer-equipped FryersRemove burners to gain access to temperature probe Replacing the High-limit Thermostat Installing the New Temperature ProbeRemove screws arrows securing high-limit to fryer Decathlon Series GAS Fryers Service Procedures Switch Guard Replacing Rocker SwitchesDecathlon Series GAS Fryers Service Procedures Replacing the Frypot Replacing the Pilot AssemblyRemoving capping strip Removing flue cap Holding backup while unscrewing flare nut on oil-return line 19. a .5 drains Loosening burner bolts prior to burner removal Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Cutting frypot seal prior to frypot removal Ignition Failure Troubleshooting and Problem IsolationImproper Burner Function Gas ValveDecathlon Series GAS Fryers Service Procedures Improper Computer Function Improper Temperature ControlImproper Filtration Function Frypot Leakage Improper Basket Lift Function Bell-Crank Basket Lifts Improper Basket Lift Function Modular Basket Lifts Improper Basket Lift Function Troubleshooting GuidesNot possible Decathlon, Electronic Ignition, Current Configuration Wiring DiagramsDecathlon, Dual Vat Thermatron Decathlon Series GAS Fryers Service Procedures Transformer Box Decathlon Interface Board Dean Oil Return Wiring Filtration and Basket Lifts PBI OIL Return Micro SwitchOil Return, Left-hand, Normally Open Float Switch Basket Lift, with Timer CM4-S with Constant Pilot Chili’s Wiring Diagram Chili’s Wiring with SCF Filtration Decathlon Primary Components Decathlon Series GAS Fryers Parts ListDecathlon D20 Primary Components Decathlon Series GAS Fryers Parts ListDecathlon 20 Primary Components Decathlon D50 Primary Components826-1871 Decathlon D50 Primary Components 211-2787 826-2229 Decathlon D60 Primary ComponentsDecathlon D60 Primary Components 106-1703SP 823-3948SP Decathlon FPD65 Primary Components212-4570 823-3494SP Decathlon D80 Primary ComponentsSee Optional Components, Section Decathlon D80 Primary Components Control Panels Control Panel Options, Joiner Strips, and Accessories16 17 Optional Components and ControllersSee Control Panel Options, Section Not illustrated Transformers & Component Boxes Multi-batteried Decathlons 823-3242 PartTo Drain Drain Valve Components 823-3221Decathlon Series GAS Fryers Parts List Flush Oil Drain Line Decathlon Series GAS Fryers Parts List Component Oil Return Manifold Components SCFD, CFD, & FPD65 ModelsOil Return and Oil Flush Components D & FPD65 Models Oil Return and Oil Flush ComponentsOil Suction Start Fitting Oil Return and Oil Flush Components D & FPD65 Models2122 Microswitch Bracket Assembly, Oil Return Decathlon Series GAS Fryers Parts List Description UFF Filtration Components SCFD50 Series FryersUFF Filtration Components D60 and D80 Series Fryers 106-1220SP Filter Pan Scfd UFF Filtration Components SCFD60 and FPD65 Series FryersUFF Filtration Components SCFD80 Series Fryers 823-3796 Suff Filtration Components CFD50 Series Fryers 823-3774 Suff Filtration Components D60 and D80 Series Fryers823-5420 Suff Filtration Components CFD60 and CFD80 Series Fryers…2.10 Basket Lift Components D50, D60, and D80 Models Basket Lift Components D50, D60, and D80 Series Fryers Decathlon Series GAS Fryers Parts List Service Hotline