Frymaster SCFD, FPD manual Holding backup while unscrewing flare nut on oil-return line

Page 29

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.8 Replacing the Frypot (cont.)

13.Remove steel line from oil-return valve and nipple by loosening flare fittings on both ends. Hold backup with an adjustable wrench when removing fittings.

(Prior to removal, absorbent cloth or paper towels should be placed under the oil line to catch any oil remaining in the lines.)

Holding backup while unscrewing flare nut on oil-return line.

14.Unscrew both flare fittings completely prior to line removal. Remove oil-return line and set aside (see Step 15 if line does not disengage easily).

Remove oil-return line after disconnecting flare nuts.

15.Turning the oil-return valve slightly outward with a pipe wrench or similar tool will facilitate return-line removal.

16.Remove four bolts securing flue to the frypot being removed. Remove the flue by sliding back and away until clear of frypot. Retrieve any screws dropped into the flue during removal of the flue cap and frypot bracket.

17.Remove oil-return valve from frypot (see Step 15, above, for more information). Turn the valve assembly counter-clockwise to remove. If nipple remains in frypot, remove it also. Set aside for reassembly. (Skip to 19B if unit has 3” round drains.)

Turn the oil-return valve slightly outward to facilitate removal of the oil-return line.

Removing bolts (arrows) securing flue to frypot.

1-24

Image 29
Contents CFD, SCFD, FPD Hour Service HotlinePage Computers FCC Table of Contents Finding Your WAY around the Dean Decathlon CE only Altitudes of 2000 feet or less Functional DescriptionNON-CE Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options Interface Boards Interface Board P/N Current Flow Through Interface Thermostats Accessing Fryers for ServicingRestraints Adjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Adjusting the Pilot FlameMain Pilot Trailing PilotBackup Operating Thermostat Optional Replacing the Computer Replacing Fryer ComponentsReplacing the Backup Thermostat if applicable Drains Replacing the Temperature Probe Computer-equipped FryersRemove burners to gain access to temperature probe Replacing the High-limit Thermostat Installing the New Temperature ProbeRemove screws arrows securing high-limit to fryer Decathlon Series GAS Fryers Service Procedures Switch Guard Replacing Rocker SwitchesDecathlon Series GAS Fryers Service Procedures Replacing the Frypot Replacing the Pilot AssemblyRemoving capping strip Removing flue cap Holding backup while unscrewing flare nut on oil-return line 19. a .5 drains Loosening burner bolts prior to burner removal Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Cutting frypot seal prior to frypot removal Ignition Failure Troubleshooting and Problem IsolationImproper Burner Function Gas ValveDecathlon Series GAS Fryers Service Procedures Improper Computer Function Improper Temperature ControlImproper Filtration Function Frypot Leakage Improper Basket Lift Function Bell-Crank Basket Lifts Improper Basket Lift Function Modular Basket Lifts Improper Basket Lift Function Troubleshooting GuidesNot possible Decathlon, Electronic Ignition, Current Configuration Wiring DiagramsDecathlon, Dual Vat Thermatron Decathlon Series GAS Fryers Service Procedures Transformer Box Decathlon Interface Board Dean Oil Return Wiring Filtration and Basket Lifts PBI OIL Return Micro SwitchOil Return, Left-hand, Normally Open Float Switch Basket Lift, with Timer CM4-S with Constant Pilot Chili’s Wiring Diagram Chili’s Wiring with SCF Filtration Decathlon Primary Components Decathlon Series GAS Fryers Parts ListDecathlon D20 Primary Components Decathlon Series GAS Fryers Parts List826-1871 Decathlon 20 Primary ComponentsDecathlon D50 Primary Components Decathlon D50 Primary Components 211-2787 826-2229 Decathlon D60 Primary ComponentsDecathlon D60 Primary Components 106-1703SP 823-3948SP Decathlon FPD65 Primary Components212-4570 823-3494SP Decathlon D80 Primary ComponentsSee Optional Components, Section Decathlon D80 Primary Components Control Panels Control Panel Options, Joiner Strips, and Accessories16 17 Optional Components and ControllersSee Control Panel Options, Section Not illustrated Transformers & Component Boxes Multi-batteried Decathlons 823-3242 PartTo Drain Drain Valve Components 823-3221Decathlon Series GAS Fryers Parts List Flush Oil Drain Line Decathlon Series GAS Fryers Parts List Component Oil Return Manifold Components SCFD, CFD, & FPD65 ModelsOil Return and Oil Flush Components D & FPD65 Models Oil Return and Oil Flush ComponentsOil Suction Start Fitting Oil Return and Oil Flush Components D & FPD65 Models2122 Microswitch Bracket Assembly, Oil Return Decathlon Series GAS Fryers Parts List Description UFF Filtration Components SCFD50 Series FryersUFF Filtration Components D60 and D80 Series Fryers 106-1220SP Filter Pan Scfd UFF Filtration Components SCFD60 and FPD65 Series FryersUFF Filtration Components SCFD80 Series Fryers 823-3796 Suff Filtration Components CFD50 Series Fryers 823-3774 Suff Filtration Components D60 and D80 Series Fryers823-5420 Suff Filtration Components CFD60 and CFD80 Series Fryers…2.10 Basket Lift Components D50, D60, and D80 Models Basket Lift Components D50, D60, and D80 Series Fryers Decathlon Series GAS Fryers Parts List Service Hotline