Frymaster FPD, SCFD manual Decathlon Interface Board

Page 51

 

 

 

LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

LEFT

 

 

 

 

 

 

 

 

 

RIGHT

 

 

 

TEMP

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP

 

 

 

PROBE

 

C

 

 

 

NO

 

 

 

 

 

 

 

NO

 

 

 

NC

 

 

 

PROBE

 

 

 

 

 

NC

 

 

12V

R2

24V

 

 

 

 

 

 

 

R1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1

2

4

8

7

5

1

3

7

8

10

2

4

J3

 

 

 

 

 

 

 

 

 

 

 

F1

 

Sound

 

 

 

 

 

 

 

 

 

 

 

 

 

Device

 

 

 

 

 

 

 

 

 

 

 

 

 

Sound:

 

 

 

 

 

 

 

 

R-GV

24V

 

 

 

Terminal #1 - Loud

 

 

L-HEAT

 

L-GV

 

 

12V

 

 

 

 

R-HEAT

Terminal #2 - Medium

 

 

 

 

 

 

 

 

 

Terminal #3 - Low

 

 

 

 

 

 

 

 

 

 

 

LED 4

 

 

LED 2

 

 

 

 

 

LED 5

LED 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

LED 1

 

 

LED 6

 

 

 

 

 

R

PW

 

 

 

 

 

 

 

 

 

 

PW

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

AIR

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

RL-1

RL-3

V2D

 

V1D

1-46

SD

15

14

6

2

1

3

5

4

13

14

11

J2

15

14

6

2

1

3

5

4

13

14

11

 

 

 

 

POWE

 

 

POWE

 

 

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

T

 

 

ON/OFF

 

 

ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

A

 

 

 

 

 

 

 

 

 

RL1 = 12VDC 2PST

RL2 = 12VDC SPST (NOT USED) RL3 = 12VDC 2PST

RL4 = 12VDC SPST (NOT USED)

 

 

Interface

J1

J3

Board

V2D RL2 RL4 V1D

PWR RL1 RL3 PWR

To Terminal Tab on

Computer

Decathlon Interface Board

CHAPTER 1: SERVICE

DECATHLON SERIES

PROCEDURES

GAS FRYERS

Image 51
Contents CFD, SCFD, FPD Hour Service HotlinePage Computers FCC Table of Contents Finding Your WAY around the Dean Decathlon Functional Description NON-CE Altitudes of 2000 feet or lessCE only Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options Interface Boards Interface Board P/N Current Flow Through Interface Thermostats Accessing Fryers for ServicingRestraints Adjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableTrailing Pilot Adjusting the Pilot FlameCalibrating the Thermatron Main PilotBackup Operating Thermostat Optional Replacing the Computer Replacing Fryer ComponentsReplacing the Backup Thermostat if applicable Drains Replacing the Temperature Probe Computer-equipped FryersRemove burners to gain access to temperature probe Replacing the High-limit Thermostat Installing the New Temperature ProbeRemove screws arrows securing high-limit to fryer Decathlon Series GAS Fryers Service Procedures Switch Guard Replacing Rocker SwitchesDecathlon Series GAS Fryers Service Procedures Replacing the Frypot Replacing the Pilot AssemblyRemoving capping strip Removing flue cap Holding backup while unscrewing flare nut on oil-return line 19. a .5 drains Loosening burner bolts prior to burner removal Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Cutting frypot seal prior to frypot removal Ignition Failure Troubleshooting and Problem IsolationImproper Burner Function Gas ValveDecathlon Series GAS Fryers Service Procedures Improper Computer Function Improper Temperature ControlImproper Filtration Function Frypot Leakage Improper Basket Lift Function Bell-Crank Basket Lifts Improper Basket Lift Function Modular Basket Lifts Improper Basket Lift Function Troubleshooting GuidesNot possible Decathlon, Electronic Ignition, Current Configuration Wiring DiagramsDecathlon, Dual Vat Thermatron Decathlon Series GAS Fryers Service Procedures Transformer Box Decathlon Interface Board Dean Oil Return Wiring Filtration and Basket Lifts PBI OIL Return Micro SwitchOil Return, Left-hand, Normally Open Float Switch Basket Lift, with Timer CM4-S with Constant Pilot Chili’s Wiring Diagram Chili’s Wiring with SCF Filtration Decathlon Primary Components Decathlon Series GAS Fryers Parts ListDecathlon D20 Primary Components Decathlon Series GAS Fryers Parts ListDecathlon 20 Primary Components Decathlon D50 Primary Components826-1871 Decathlon D50 Primary Components 211-2787 826-2229 Decathlon D60 Primary ComponentsDecathlon D60 Primary Components 106-1703SP 823-3948SP Decathlon FPD65 Primary Components212-4570 823-3494SP Decathlon D80 Primary ComponentsSee Optional Components, Section Decathlon D80 Primary Components Control Panels Control Panel Options, Joiner Strips, and Accessories16 17 Optional Components and ControllersSee Control Panel Options, Section Not illustrated Transformers & Component Boxes Multi-batteried Decathlons 823-3242 PartTo Drain Drain Valve Components 823-3221Decathlon Series GAS Fryers Parts List Flush Oil Drain Line Decathlon Series GAS Fryers Parts List Component Oil Return Manifold Components SCFD, CFD, & FPD65 ModelsOil Return and Oil Flush Components D & FPD65 Models Oil Return and Oil Flush ComponentsOil Suction Start Fitting Oil Return and Oil Flush Components D & FPD65 Models2122 Microswitch Bracket Assembly, Oil Return Decathlon Series GAS Fryers Parts List Description UFF Filtration Components SCFD50 Series FryersUFF Filtration Components D60 and D80 Series Fryers 106-1220SP Filter Pan Scfd UFF Filtration Components SCFD60 and FPD65 Series FryersUFF Filtration Components SCFD80 Series Fryers 823-3796 Suff Filtration Components CFD50 Series Fryers 823-3774 Suff Filtration Components D60 and D80 Series Fryers823-5420 Suff Filtration Components CFD60 and CFD80 Series Fryers…2.10 Basket Lift Components D50, D60, and D80 Models Basket Lift Components D50, D60, and D80 Series Fryers Decathlon Series GAS Fryers Parts List Service Hotline