1.8.7 Improper Basket Lift Function

Bell-Crank Basket Lifts

Most Decathlon Series gas fryers are equipped with a bell- crank style basket lift. A cam and a bell crank are connected to the basket lift arm by a flat metal link. The cam is attached to a drive motor. The motor rotates the cam, raising or lowering the lift arm linked to the bell crank. A roller- activated microswitch is used to limit travel. When the roller in the microswitch is in contact with the cam, the motor is energized. As the cam rotates, the roller loses contact with the cam and the motor power circuit is broken, de-energizing the motor.

Timing circuitry in the controller initiates and stops basket lift operation. When the product button is pressed, the timing circuitry activates a coil in the basket lift relay to supply power to the motor. The microswitch stops the motor at the lift’s lower travel limit and the switch contacts are reversed. At the end of the programmed cooking time, the timing circuit activates the coil once more and the lift rises until the microswitch again loses contact with the cam, opening the motor power circuit and stopping the motor.

Problems with the bell-crank basket lift system can be grouped into two categories:

binds and jams or

motor and gear wear.

Binds and jams. Noisy, jerky, or erratic lift movement is usually due to lack of lubrication. Apply a light coat of Lubriplate or similar lightweight white grease to the connection points to correct the problem.

Back view of bell-crank basket lift.

Bell-crank basket-lift arms.

Motor Problems. If power is reaching the motor but the motor fails to run, the motor is burned out and must be replaced.

1-37

Image 42
Contents Hour Service Hotline CFD, SCFD, FPDPage Computers FCC Table of Contents Finding Your WAY around the Dean Decathlon Functional Description NON-CE Altitudes of 2000 feet or lessCE only Altitudes of 2000 feet or less Pilot System Configuration Electronic Ignition ConfigurationControl Options Interface Boards Interface Board P/N Current Flow Through Interface Accessing Fryers for Servicing ThermostatsRestraints Cleaning the Gas Valve Vent Tube if applicable Adjusting Burner Manifold Gas PressureMain Pilot Adjusting the Pilot FlameCalibrating the Thermatron Trailing PilotBackup Operating Thermostat Optional Replacing Fryer Components Replacing the ComputerReplacing the Backup Thermostat if applicable Replacing the Temperature Probe Computer-equipped Fryers DrainsRemove burners to gain access to temperature probe Installing the New Temperature Probe Replacing the High-limit ThermostatRemove screws arrows securing high-limit to fryer Decathlon Series GAS Fryers Service Procedures Replacing Rocker Switches Switch GuardDecathlon Series GAS Fryers Service Procedures Replacing the Pilot Assembly Replacing the FrypotRemoving capping strip Removing flue cap Holding backup while unscrewing flare nut on oil-return line 19. a .5 drains Loosening burner bolts prior to burner removal Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Decathlon Series GAS Fryers Service Procedures Cutting frypot seal prior to frypot removal Troubleshooting and Problem Isolation Ignition FailureGas Valve Improper Burner FunctionDecathlon Series GAS Fryers Service Procedures Improper Temperature Control Improper Computer FunctionImproper Filtration Function Frypot Leakage Improper Basket Lift Function Bell-Crank Basket Lifts Improper Basket Lift Function Modular Basket Lifts Troubleshooting Guides Improper Basket Lift FunctionNot possible Wiring Diagrams Decathlon, Electronic Ignition, Current ConfigurationDecathlon, Dual Vat Thermatron Decathlon Series GAS Fryers Service Procedures Transformer Box Decathlon Interface Board Dean Oil Return Wiring OIL Return Micro Switch Filtration and Basket Lifts PBIOil Return, Left-hand, Normally Open Float Switch Basket Lift, with Timer CM4-S with Constant Pilot Chili’s Wiring Diagram Chili’s Wiring with SCF Filtration Decathlon Series GAS Fryers Parts List Decathlon Primary ComponentsDecathlon Series GAS Fryers Parts List Decathlon D20 Primary ComponentsDecathlon 20 Primary Components Decathlon D50 Primary Components826-1871 Decathlon D50 Primary Components 211-2787 Decathlon D60 Primary Components 826-2229Decathlon D60 Primary Components 106-1703SP Decathlon FPD65 Primary Components 823-3948SP212-4570 Decathlon D80 Primary Components 823-3494SPSee Optional Components, Section Decathlon D80 Primary Components Control Panel Options, Joiner Strips, and Accessories Control PanelsOptional Components and Controllers 16 17See Control Panel Options, Section Not illustrated Transformers & Component Boxes Multi-batteried Decathlons Part 823-3242To Drain 823-3221 Drain Valve ComponentsDecathlon Series GAS Fryers Parts List Flush Oil Drain Line Decathlon Series GAS Fryers Parts List Oil Return Manifold Components SCFD, CFD, & FPD65 Models ComponentOil Return and Oil Flush Components Oil Return and Oil Flush Components D & FPD65 ModelsOil Return and Oil Flush Components D & FPD65 Models Oil Suction Start Fitting2122 Microswitch Bracket Assembly, Oil Return Decathlon Series GAS Fryers Parts List UFF Filtration Components SCFD50 Series Fryers DescriptionUFF Filtration Components D60 and D80 Series Fryers UFF Filtration Components SCFD60 and FPD65 Series Fryers 106-1220SP Filter Pan ScfdUFF Filtration Components SCFD80 Series Fryers 823-3796 Suff Filtration Components CFD50 Series Fryers Suff Filtration Components D60 and D80 Series Fryers 823-3774Suff Filtration Components CFD60 and CFD80 Series Fryers 823-5420…2.10 Basket Lift Components D50, D60, and D80 Models Basket Lift Components D50, D60, and D80 Series Fryers Decathlon Series GAS Fryers Parts List Service Hotline