Frymaster 8196345 manual Replacing an Ignition Module

Page 15

1.9.4 Replacing an Ignition Module

1.Disconnect the fryer from the electrical supply.

2.Lift up on the bezel to disengage the tabs on its lower edge from the control panel frame.

3.Remove the top two screws in the upper corners of the computer.

4.Swing the computer out from the top and allow it to rest on its hinge tabs.

5.Disconnect the wires from the ignition module, marking or making a note of the wires and terminals to facilitate reconnection.

6.Remove the four ignition module screws and pull the module from the component box.

7.Move the spacers to the new module.

8.Reverse the procedure to install the replacement module.

1.9.5 Replacing an Ignitor Assembly

DANGER

Drain the frypot or remove the handle from the drain valve before proceeding further.

1.Disconnect the fryer from the electrical supply.

2.Disconnect the flame sensor wire by carefully pulling its push-on terminal from the terminal strip on the ignitor. Disconnect the gas enrichment tube at the ignitor-end compression fitting. Disconnect the ignition cable from the ignitor by grasping its boot and gently pulling toward you. (See photo below)

Flame Sensor Wire

Gas Enrichment Tube

Ignition Cable

3.Remove the sheet metal screws securing the ignitor to the mounting plate and pull the ignitor from the fryer.

4.Reverse the procedure to install the replacement ignitor.

1-9

Image 15
Contents GAS Hour Service HotlineCanada Iii Protector Series GAS Fryers Table of Contents Protector Series GAS Fryers This page Intentionally Left Blank Electronic Ignition System Functional DescriptionInterface Board LED Diagnostic LightsPage Thermostats Accessing Fryers for ServicingChecking the Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube Non-CE Standard Burner Manifold Gas Pressures Measuring Flame Current Replacing the Interface Board Replacing the Temperature Probe or High-Limit ThermostatReplacing an Ignition Module Replacing or Cleaning a Combustion Air Blower Adjusting the Air/Gas Mixture ALL Other Valves Replacing a Gas ValveReplacing a Burner Assembly Replacing the Frypot Page Replacing Frypot Insulation and/or Upper Burner Rails Full Vat IllustratedPage Re-assembling a Frypot Full-Vat Illustrated Ignition Failure Troubleshooting and Problem IsolationImproper Burner Function Improper Temperature Control Filtration Malfunctions Computer MalfunctionsVerifying Solenoid Operation Basket Lift Malfunctions LeakageBinds and Jams VAC is not present on the interface board J3 pin 9 LED 5 GV Troubleshooting Guides Troubleshooting the 24 VAC CircuitPage Replacing the Transformer or Filter Relay Troubleshooting the Gas ValveATO Automatic Top-Off Service Procedures Probe Resistance ChartATO Automatic Top-Off Troubleshooting Problem Probable Causes Corrective ActionATO Automatic Top-Off Board Pin Positions and Harnesses 8074646 Function Voltage Wire ColorReplacing the ATO Pump or Solenoid Replacing the ATO Board or TransformerLow temp Hot-hi-1Failure with IgNITIONFailure Enter Setup in Tech Mode Enter Reset Recovery Fault Call Service Enter14.2 CM7 Useful Codes 14.3 CM7 Menu Summary Tree 14.4 CM7 Board Pin Positions and Harnesses To update CM7 and ATO software follow these steps Principal Wiring Connections Wiring Diagrams Main Page FPGL330 Transformer / Filter Box Domestic Modular Basket Lift 100/120V Modular Basket Lift 208/250V FPGL30 Series FULL-VAT with ONE DUAL-SPARK Ignition Module Simplified Wiring Diagrams FPGL30 Series Full VatFPGL30 Series Full Vat Australia and Pacific Rim FPGL30 Series FULL-VAT Australia and Pacific RIMFPGL30 Series Simplified Wiring FPGL30 Series Data Network Flowchart Accessories Protector Series GAS Fryers Parts ListBasket Lift Assembly and Associated Parts Component Doors, Sides, Flue Caps, Top Caps and Casters Drain System Components Drain Valves and Associated Parts Drain Tube Sections and Associated Parts Electronics and Electrical Components 2.5.1 Component Boxes Fuse 5A 125V International Only Component BoxesTransformer Boxes FPGL230 Computers and Associated Components Wiring Main Wiring Harnesses 2 CM7 and ATO Wiring Harnesses Refer to wiring diagram on Page Full-Vat Frypot Components Frypot Assemblies and Associated Parts FPGL30 Full Vat Gas Manifold Typical Gas Supply and Combustion System ComponentsComponent Gas Valves and Associated Components Valve, Non-CE Gas Filtration System Components Component Return Valve Assembly and Associated Parts ATO Automatic Top-Off Board ComponentJIB Cradle, JIB/BIB Cap and Pick Up Assembies ATO Automatic Top-Off Solenoid and Pump AssembliesWiring Connectors, Pin Terminals and Tools Fasteners Fasteners This page Intentionally Left Blank Service Hotline