relay marking the wires to ease reassembly. Once replaced, reconnect the power. When replacing a filter relay in the transformer, ensure the 24VAC relay (8070012) is used.
1.12Probe Resistance Chart
Probe Resistance Chart
For use with Protector® Series fryers manufactured with Minco Thermistor probes only.
F | OHMS | C |
60 | 1059 | 16 |
65 | 1070 | 18 |
70 | 1080 | 21 |
75 | 1091 | 24 |
80 | 1101 | 27 |
85 | 1112 | 29 |
90 | 1122 | 32 |
95 | 1133 | 35 |
100 | 1143 | 38 |
105 | 1154 | 41 |
110 | 1164 | 43 |
115 | 1174 | 46 |
120 | 1185 | 49 |
125 | 1195 | 52 |
F | OHMS | C |
130 | 1204 | 54 |
135 | 1216 | 57 |
140 | 1226 | 60 |
145 | 1237 | 63 |
150 | 1247 | 66 |
155 | 1258 | 68 |
160 | 1268 | 71 |
165 | 1278 | 74 |
170 | 1289 | 77 |
175 | 1299 | 79 |
180 | 1309 | 82 |
185 | 1320 | 85 |
190 | 1330 | 88 |
195 | 1340 | 91 |
F | OHMS | C |
200 | 1350 | 93 |
205 | 1361 | 96 |
210 | 1371 | 99 |
215 | 1381 | 102 |
220 | 1391 | 104 |
225 | 1402 | 107 |
230 | 1412 | 110 |
235 | 1422 | 113 |
240 | 1432 | 116 |
245 | 1442 | 118 |
250 | 1453 | 121 |
255 | 1463 | 124 |
260 | 1473 | 127 |
265 | 1483 | 129 |
F | OHMS | C |
270 | 1493 | 132 |
275 | 1503 | 135 |
280 | 1514 | 138 |
285 | 1524 | 141 |
290 | 1534 | 143 |
295 | 1544 | 146 |
300 | 1554 | 149 |
305 | 1564 | 152 |
310 | 1574 | 154 |
315 | 1584 | 157 |
320 | 1594 | 160 |
325 | 1604 | 163 |
330 | 1614 | 166 |
335 | 1624 | 168 |
F | OHMS | C |
340 | 1634 | 171 |
345 | 1644 | 174 |
350 | 1654 | 177 |
355 | 1664 | 179 |
360 | 1674 | 182 |
365 | 1684 | 185 |
370 | 1694 | 188 |
375 | 1704 | 191 |
380 | 1714 | 193 |
385 | 1724 | 196 |
390 | 1734 | 199 |
395 | 1744 | 202 |
400 | 1754 | 204 |
405 | 1764 | 207 |
1.13 ATO (Automatic Top-Off) Service Procedures
The automatic
The ATO board is located inside the box, behind the JIB (see Figure 1). The power for the ATO board is supplied from the transformer box. The power passes through the transformer inside the ATO box to the board.
Figure 1