"address +1" will be transmitted (e.g. when A3 is programmed as the base address then the Marmitek X10 address A4 will be sent by using input 2). If the status in the MicroModule was ON, an OFF command will be transmitted. If the status in the MicroModule was OFF, an ON command will be transmitted. Through this transmission, other Marmitek X10 modules can be switched remotely over the power line or Macro’s setup in the computer interface can be activated.
Mounting Instructions
WARNING! ALWAYS SWITCH OFF THE MAIN MASTER SWITCH BEFORE INSTALLING THE MICROMODULE.
To install the MicroModule AWM2 the following wiring is required at the module installation point.
1.Neutral
2.Phase 230V
3.Load. This wire runs directly to the load.
•Take the wall switch out of the wall outlet.
•Disconnect all wires from the switch.
•Pull an additional
MICROMODULE AWM2 | 5 |