Jenn-Air W10298937B Install Cooktop, Make Electrical Connection, Electrical Connection Options

Page 10

Install Cooktop

1.Using 2 or more people, place cooktop right side up into the cutout.

NOTE: Make sure that the front edge of the cooktop is parallel to the front edge of the countertop. If repositioning is needed, lift entire cooktop up from the cutout to avoid scratching the countertop.

2.Connect blower exhaust scroll to ducting.

3.Use vent clamps to secure the ducting to the blower exhaust scroll.

4.Turn tie down bolts clockwise until they contact the bottom side of the countertop, then tighten ¹⁄₄ turn more.

5.Install grease container(s) to bottom of cooktop.

6.Reinstall grease filter.

7.Reinstall vent grille.

Make Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire.

Electrically ground cooktop.

Failure to follow these instructions can result in death, fire, or electrical shock.

This cooktop is manufactured with a white (neutral) power supply wire twisted together with a green (or bare) grounding wire connected to the cooktop.

Home power supply cable and connectors are not provided.

See the “Electrical Connection Options” chart to complete installation for your type of electrical connection.

Electrical Connection Options

If your home has:

And you will be

Go to Section:

 

connecting to:

 

4-wire

A fused

4-Wire Cable from

 

disconnect or

Power Supply

 

circuit breaker

 

½"

box

 

 

 

(1.3 cm)

 

 

3-wire

A fused

3-Wire Cable from

 

disconnect or

Power Supply

 

circuit breaker

 

 

box

 

½"

 

 

(1.3 cm)

 

 

4-Wire Cable from Home Power Supply to 4-Wire Cable to Cooktop

IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction, and in Canada.

E

A

B F

CG

 

H

D

 

A. Green (or bare) ground wires

E. Plenum wiring box

B. White wires

F. Red wires

C. Black wires

G. UL listed wire connector

D. Cable from home power supply

H. UL listed or CSA approved

 

strain relief

1.Disconnect power.

2.Remove wiring box cover from the cooktop plenum.

3.Remove the appropriate knockout for the size of the home power supply cable on the bottom side of the cooktop wiring box. Use a UL listed or CSA approved strain relief to connect home power supply cable to cooktop wiring box.

4.Connect the green (or bare) ground wire from the home power supply to the green (or bare) ground wire in the plenum wiring box using the UL listed wire connectors.

5.Connect the 2 black wires together using the UL listed wire connectors.

6.Connect the 2 red wires together using the UL listed wire connectors.

7.Connect the 2 white wires together the UL listed wire connectors.

8.Tighten screws on the strain relief.

9.Install cooktop wiring box cover on plenum wiring box.

10

Image 10
Contents Cooktop Safety Table of Contents/Table des matièresTools and Parts Installation RequirementsLocation Requirements Cabinet Dimensions 45 114.3 cm CooktopVenting Requirements Cutout DimensionsFor Best Performance Makeup Air Cold Weather InstallationsVenting Methods Option 1 Roof Venting Option 2 Wall VentingCalculating Vent System Length Concrete Slab Installations Exhaust Through WallConcrete Slab Installations Exhaust Through Window Well Vent Piece Cm RoundExample vent system Determine Range Blower SettingElectrical Requirements To Convert to High RangePrepare Cooktop Before You Make the Electrical ConnectionTo rotate blower motor Rotate Blower OptionalTo rotate blower Make Electrical Connection Install CooktopIf your home has You will be Go to Section Connecting to Electrical Connection OptionsComplete Installation If you need Assistance or ServicePage Sécurité DE LA Table DE Cuisson Exigences DinstallationExigences d’emplacement Outillage et piècesDimensions du produit Table de cuisson de 30 76,2 cm Table de cuisson de 45 114,3 cmDimensions du placard Dimensions de l’ouverture à découperPour obtenir la meilleure performance Installations pour régions à climat froidExigences concernant lévacuation Air d’appointMéthodes dévacuation La caisseExemple de circuit dévacuation Conversion au mode à forte aspirationCalcul de la longueur effective du circuit dévacuation Détermination du réglage du ventilateurSpécifications électriques Avant d’établir la connexion électriqueRotation du ventilateur Facultative Instructions D’INSTALLATIONPréparation de la table de cuisson Pour faire pivoter le ventilateurRaccordement électrique Installation de la table de cuissonPour faire pivoter le moteur du ventilateur Câblage de la maison Point de Options de raccordement électriqueDistribution Suivante Achever linstallation Si vous avez besoin dassistance ou de service2012 All rights reserved