Rotate Blower - Optional
IMPORTANT: The following additional steps must be performed if the product is being installed in peninsula or island cabinetry.
The blower exhaust scroll is shipped from the factory set to exhaust straight out the back of the cabinet through an exterior wall.
To rotate blower motor:
1.Using a ratchet with a ³⁄₈" socket and supporting the motor with one hand, remove the four machine nuts that attach the blower motor to the exhaust scroll.
2.Remove the blower motor and wheel assembly from the weld studs.
D
C D
AB
E
A.Blower exhaust scroll
B.Plenum
C.Blower motor
D.
E.Motor mounting plate
C
A
B
A. Blower motor
B. Motor mounting plate
C. Weld stud location
To rotate blower:
1.Remove the vent grille and grease filter.
2.Using a ³⁄₈" socket on a ratchet, reach into the plenum and loosen the four
3.With the nuts loosened, the blower exhaust scroll can be easily rotated downward.
3.When the motor mounting plate clears the threaded weld studs, rotate the assembly clockwise 90° and reinstall the four
4.Retighten each nut with the ³⁄₈" socket and ratchet.
5.Reinstall the grease filter and vent grille.
9