Jenn-Air W10298937B installation instructions 45 114.3 cm Cooktop, Cabinet Dimensions

Page 3

45" (114.3 cm) Cooktop

C

B

AD

E

F

A. Tie down bolt (on each side of cookop)

B. 45" (114.3 cm)

C. 21³⁄₄" (55.3 cm)

D. Grease containers

E. Wiring box cover

F. Blower

Cabinet Dimensions

A

D

CB

L FG

E

H

I

KJ

B

A*

C

D**

E

A. 6¹⁄₄" (15.9 cm) B. 3¹⁄₂" (8.9 cm)

C. Grease containers D. 2" (5.1 cm)

G

C

H

F

E. 13³⁄₄" (34.9 cm)

F.26³⁄₄" (68.0 cm) G. 4" (10.2 cm)

H. 13¹¹⁄₁₆" (35.1 cm)

A. 30" (76.2 cm) on 30" (76.2 cm) models 45" (114.3 cm) on 45" (114.3 cm) models

B. Combustible area above countertop (shown by dashed box above)

C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is covered by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)

D. 13" (33 cm) recommended upper cabinet depth E. 1⁷⁄₈" (4.8 cm) min.

F. 21" (53.3 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop

*A minimum clearance of 6¹⁄₄" (15.9 cm) is recommended for removal of the grease containers. Installed dimension for the grease containers is 5¹⁄₂" (14.0 cm).

**A minimum clearance of 2" (5.1 cm) is recommended between the motor/blower and cabinet for proper cooling.

H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of countertop

I. Junction box or outlet; 10" (25.4 cm) from right-hand side of cabinet

J. 29¹⁄₁₆" (73.9 cm) on 30" (76.2 cm) models 43¹⁄₄" (109.9 cm) on 45" (114.3 cm) models

K. 2½" (6.4 cm) minimum distance to nearest left and right side combustible surface above cooktop

L. 1½" (3.8 cm) minimum clearance between back wall and countertop

3

Image 3
Contents Table of Contents/Table des matières Cooktop SafetyInstallation Requirements Tools and PartsLocation Requirements 45 114.3 cm Cooktop Cabinet DimensionsCutout Dimensions Venting RequirementsFor Best Performance Option 1 Roof Venting Option 2 Wall Venting Cold Weather InstallationsVenting Methods Makeup AirVent Piece Cm Round Concrete Slab Installations Exhaust Through WallConcrete Slab Installations Exhaust Through Window Well Calculating Vent System LengthTo Convert to High Range Determine Range Blower SettingElectrical Requirements Example vent systemBefore You Make the Electrical Connection Prepare CooktopRotate Blower Optional To rotate blower motorTo rotate blower Electrical Connection Options Install CooktopIf your home has You will be Go to Section Connecting to Make Electrical ConnectionIf you need Assistance or Service Complete InstallationPage Outillage et pièces Exigences DinstallationExigences d’emplacement Sécurité DE LA Table DE CuissonTable de cuisson de 45 114,3 cm Dimensions du produit Table de cuisson de 30 76,2 cmDimensions de l’ouverture à découper Dimensions du placardAir d’appoint Installations pour régions à climat froidExigences concernant lévacuation Pour obtenir la meilleure performanceLa caisse Méthodes dévacuationDétermination du réglage du ventilateur Conversion au mode à forte aspirationCalcul de la longueur effective du circuit dévacuation Exemple de circuit dévacuationAvant d’établir la connexion électrique Spécifications électriquesPour faire pivoter le ventilateur Instructions D’INSTALLATIONPréparation de la table de cuisson Rotation du ventilateur FacultativeInstallation de la table de cuisson Raccordement électriquePour faire pivoter le moteur du ventilateur Options de raccordement électrique Câblage de la maison Point deDistribution Suivante Si vous avez besoin dassistance ou de service Achever linstallation2012 All rights reserved