TROUBLESHOOTING - WFAE-55FS (Solid State Controls)

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

 

Unit disconnected from electric power

Reconnect to power

 

 

Check/reset circuit breaker

 

 

 

 

Menu temp not programmed or set too

Program menu key for desired

Fryer will not heat

low

temperature

 

 

 

Hi-Limit thermostat (item 9) tripped

Allow unit to cool, reset hi-limit

 

 

See page 3

 

 

 

 

Internal damage

Contact your Authorized Wells Service

 

 

Agency for repairs

 

 

 

 

Menu key not programmed for time, or

Program menu key for desired time.

 

programmed to 00:00

Be sure to press BASKET + DOWN to

Lift cradle will not lower

 

lower basket.

 

 

Internal damage or mis-adjustment

Contact your Authorized Wells Service

 

 

 

Agency for repairs

 

 

 

 

PAUSE pressed

Be sure to press BASKET + DOWN to

 

lower basket. Press PAUSE when

 

 

basket is down to resume

 

 

 

 

Lift cradle not properly assembled to lift

Properly assemble cradle pivot to lift rod

Lift cradle will not raise

rod

 

 

 

Internal damage or mis-adjustment

Contact your Authorized Wells Service

 

 

 

Agency for repairs

 

 

 

 

Switches not set for filtering

Press power switch (item 1) to FILTER

 

 

Press pump filter switch (item 6) to ON

 

 

 

Filter pump will not run

Pump overload (item 9) tripped

Reset overload. Press red button until it

 

“clicks” and stays locked in

 

 

 

 

 

 

Internal damage (pump overload trips

Contact your Authorized Wells Service

 

frequently)

Agency for repairs

 

 

 

 

Drain valve (item 11) not properly set

Oil level in reservoir must be monitored

 

 

at all times while filtering. Adjust flow by

 

 

opening or closing drain valve

Filter reservoir overflows

 

 

Filter leaf surface clogged with crumbs or

Turn drain valve OFF. When bubbles

during filter cycle

other cooking debris

begin appearing in frypot turn filter pump

 

 

switch OFF. Carefully slide reservoir out

 

 

12” and clear surface of filter leaf with

 

 

hi-temp brush or wooden dowel. Rein-

 

 

stall reservoir and resume filtering.

 

 

 

 

Filter leaf not properly assembled or not

Reassemble filter leaf. Be sure o-ring is

 

properly installed

in place, o-ring receptacle is clean and

Does not filter completely

 

filter leaf is properly installed in reservoir.

 

 

 

Filter leaf screen damaged

Replace filter leaf

 

 

 

 

Filter leaf o-ring damaged

Replace filter leaf o-ring

 

 

 

 

Suction tube not seated, allowing air to

When inserting filter reservoir be sure

 

enter system

suction tube is fully seated in suction line

Filter pump won’t pump, or pumps air

 

receptacle.

 

 

when filtering

Suction tube o-ring damaged

Replace suction tube o-ring

 

 

 

 

Internal damage

Contact your Authorized Wells Service

 

 

Agency for repairs

 

 

 

 

 

NOTE: There are no user serviceable

 

 

components in the fryer. In all cases of

 

 

damage or malfunction, contact your

 

 

Authorized Wells Service Agency for

 

 

repairs.

 

 

 

363 300007 OpManual for WFAE-50F/FS Electric Fryer

32

Image 34
Contents WFAE-55F 363 300007 OpManual for WFAE-50F/FS Electric Fryer Power DimensionsElectrical Specifications Domestic Export EU Voltage CapacitiesBuzzer Switch Power SwitchTimer Filter Pump SwitchReset Button Temperature ControlPower Outlet BOX Heater Interlock SwitchDigital Readout Time KEYTemp KEY UP Arrow KEYContact Block SonalertFor Units with Solid Shortening Melt Option Heater363 300007 OpManual for WFAE-50F/FS Electric Fryer STD E6070363 300007 OpManual for WFAE-50F/FS Electric Fryer Field Wiring WVAE-55FPRE-CLEANING Procedure Burn HazardWVAE-55FSPRE-CLEANING Procedure Burn HazardLift Cradle ReservoirFor Fryers with Vent Hood WVAE-55… Solid Shortening Melt OPTION. do not USE LardDetermine Maximum Load Weight Burn Hazard SET Cook Timer and Load ProductPRE-HEATING Fryer Cook Cycle and BuzzerProgramming KEY Functions Program Menu Times and Temperatures Using Function Keys Operation WFAE-55FSPRE-HEAT the Fryer To Cook ProductDrain Heater Safety Switch Cleaning Instructions Electric Shock HazardCleaning Instructions Frequency PreparationTools Filter Leaf Assembly Bottom ScreenFiltering OIL 363 30007 OpManual for WFAE-55F/FS Electric Fryer Remember HOT OIL will Burn YOUOIL Disposal Container 4 NPT Street Elbow Immediately Cradle Lift LubricationCradle Roller Assemblies Keep Them TightTroubleshooting WFAE-55F Manual Controls Symptom Possible Cause Suggested RemedyTroubleshooting WFAE-55FS Solid State Controls 363 30007 OpManual for WFAE-55F/FS Electric Fryer Wells

WFAE-55FS, WFAE-55F specifications

The Bloomfield WFAE-55F and WFAE-55FS are two highly regarded commercial coffee brewers that have gained popularity in cafés, restaurants, and convenience stores. Designed with the professional barista in mind, both models embody efficiency, durability, and stellar brewing technology, ensuring that each cup is crafted to perfection.

One of the key features of the WFAE-55F and WFAE-55FS is their ability to brew large quantities of coffee effortlessly. Both models are equipped with a dual-function brewer that allows for simultaneous brewing and dispensing, making it ideal for high-traffic environments. With a capacity of up to 55 cups at a time, operators can meet the demands of busy service periods without compromising on taste or quality.

Both models are constructed with stainless steel, ensuring not only durability but also a contemporary aesthetic that fits seamlessly into any modern kitchen. The materials used in the construction allow for easy cleaning and maintenance, keeping hygiene standards high. Additionally, the brewers are designed to withstand the rigors of daily use, making them a sound investment for any serious coffee business.

The WFAE-55F and WFAE-55FS also feature advanced brewing technology that supports precision brewing. The temperature control system guarantees the water is heated to the optimal range for extraction, ensuring that the rich flavors and aromas of the coffee beans are fully realized. The controlled flow rate enhances the brewing process, allowing for even saturation of coffee grounds, which further improves the consistency of each brew.

Another significant characteristic of the WFAE-55F and WFAE-55FS is their user-friendly interface. The intuitive controls allow baristas to adjust brewing times and temperatures easily, adapting to different types of coffee and individual preferences. This versatility proves beneficial for establishments that offer a wide range of coffee options.

Both models support the use of paper filters, streamlining the brewing process while maintaining quality. Moreover, their compact design, coupled with robust functionality, makes them suitable for a variety of settings, from small cafés to large dining establishments.

In conclusion, the Bloomfield WFAE-55F and WFAE-55FS coffee brewers represent the ideal fusion of advanced brewing technology, durability, and user-centric design. Their capacity to produce large quantities of high-quality coffee makes them invaluable tools for any commercial coffee operation, providing both efficiency and remarkable flavor in every cup brewed.