Bloomfield WFAE-55FS operation manual Cleaning Instructions

Page 25

CLEANING INSTRUCTIONS (continued)

WFAE-55F (Manual Controls) HOT BOIL-OUT PROCEDURE

WARNING

WARNING:

BURN HAZARD

TURN THERMOSTAT TO LOWEST TEMPERATURE SETTING

(FULLY COUNTERCLOCKWISE)

USE ONLY LOW-FOAMING COMMERCIAL FRYER CLEANSER.

CAREFULLY FOLLOW CLEANSER INSTRUCTIONS AND WARNINGS.

DO NOT LEAVE FRYER UNATTENDED

WHILE BOILING OUT FRYPOT.

WHEN WATER BEGINS FOAMING,

BE PREPARED TO TURN POWER SWITCH OFF.

Boiling water and splatter can result in moderate to serious injury.

363 30007 OpManual for WFAE-55F/FS Electric Fryer

PREPARATION Drain oil from fryer before cleaning

FREQUENCY Monthly, or as needed

TOOLS Low-foaming commercial fryer cleanser Metal disposal container

Press POWER SWITCH OFF.

Close DRAIN VALVE (lever horizontal). Fill FRYPOT with 4 gallons of cold water.

Press POWER SWITCH to FRYER.

When water comes to a full boil, press POWER SWITCH OFF. When boiling ceases, slowly add and stir in the LOW FOAMING COMMERCIAL FRYER CLEANSER. Using the HIGH TEMPERATURE BRUSH supplied with the fryer, stir until the cleanser is completely dissolved.

Press POWER SWITCH to FRYER. When the water begins to boil, press POWER SWITCH OFF. When the boiling subsides, again press POWER SWITCH to FRYER. Repeat this procedure continuously for five (5) minutes.

Press POWER SWITCH OFF. Allow the solution to set for thirty (30) minutes.

Allow solution to cool to 120ºF (49ºC) or less before draining.

Place a suitable METAL container under the DRAIN VALVE. Open DRAIN VALVE (lever vertical) to drain the cleaning solution.

NOTE: Drain no more than 4” at a time into the container to prevent splashing and spilling. Dispose of used solution as required by local ordinances.

Rinse frypot with clean water. Dry with a soft clean cloth.

IMPORTANT:

Use a LOW-FOAMING COMMERCIAL fryer cleanser only.

IMPORTANT:

DO NOT press FRYER-OFF- FILTER SWITCH to FILTER with anything other than shortening in the filter reservoir. Water and/or cleaning chemicals can:

cause severe oil splatter

damage the filter pump

contaminate cooking oil and food product.

23

Image 25
Contents WFAE-55F 363 300007 OpManual for WFAE-50F/FS Electric Fryer Electrical Specifications Domestic Export EU Voltage DimensionsPower CapacitiesTimer Power SwitchBuzzer Switch Filter Pump SwitchPower Outlet BOX Temperature ControlReset Button Heater Interlock SwitchTemp KEY Time KEYDigital Readout UP Arrow KEYFor Units with Solid Shortening Melt Option SonalertContact Block Heater363 300007 OpManual for WFAE-50F/FS Electric Fryer E6070 STD363 300007 OpManual for WFAE-50F/FS Electric Fryer Field Wiring Burn Hazard WVAE-55FPRE-CLEANING ProcedureBurn Hazard WVAE-55FSPRE-CLEANING ProcedureReservoir Lift CradleSolid Shortening Melt OPTION. do not USE Lard For Fryers with Vent Hood WVAE-55…Determine Maximum Load Weight PRE-HEATING Fryer SET Cook Timer and Load ProductBurn Hazard Cook Cycle and BuzzerProgramming KEY Functions Program Menu Times and Temperatures Operation WFAE-55FS Using Function KeysTo Cook Product PRE-HEAT the Fryer Drain Heater Safety Switch Electric Shock Hazard Cleaning InstructionsCleaning Instructions Frequency PreparationTools Bottom Screen Filter Leaf AssemblyFiltering OIL 363 30007 OpManual for WFAE-55F/FS Electric Fryer HOT OIL will Burn YOU RememberOIL Disposal Container 4 NPT Street Elbow Cradle Roller Assemblies Cradle Lift LubricationImmediately Keep Them TightSymptom Possible Cause Suggested Remedy Troubleshooting WFAE-55F Manual ControlsTroubleshooting WFAE-55FS Solid State Controls 363 30007 OpManual for WFAE-55F/FS Electric Fryer Wells