SERVICING INSTRUCTIONS (continued)

7. Set the tank back into the brewer. Reassemble the tank lid to

the water tank. Make sure the gasket is properly in place, then reinstall the hold-down strap.

8.Reinstall wiring to heating element and thermostat. Reinstall the hi-limit thermostat (if removed). For brewers with hot water faucet, reassemble faucet piping. Verify that all internal components are dry, then reinstall the top panel.

10.Reconnect brewer to electrical supply and, for automatic brewers, reconnect water supply.

11.Install the brew chamber without filter paper or grounds. Run at least three full brew cycles and discard all water generated.

12.Brewer is ready to use.

NOTE: Normally, silicone hoses do not need to be delimed. Should deliming hoses become necessary, Bloomfield recommends replacing the hoses.

27

Image 29
Contents 600 Introduction Safety Warnings and PrecautionsTable of Contents PLUMBER’S Installation Instructions InstallationElectrical Damage Unstable Equipment HazardShock Hazard ELECTRICIAN’S Installation InstructionsBrewer CHECK-OUT Brewer Overall CHECK-OUTBurn Hazard Preparation Brewing CoffeePOUR-OVER Operation Automatic OperationProcedure Clean Coffee Brewer Cleaning InstructionsTheory of Operation POUR-OVER FeatureHOT Water Faucet Brew Water Temperature Control Quick Guide Troubleshooting GuideTroubleshooting Guide Troubleshooting Guide Brew Water System Automatic Brew Water System Automatic or POUR-OVER Operation Brew Water System POUR-OVER Operation Faucet Water System Troubleshooting Guide Troubleshooting Guide Electric Shock Hazard Electrical System Heating Troubleshooting Guide Servicing Instructions Temperature AdjustmentRemove Tank LID Assembly Timer AdjustmentReplace Thermostat Replace Heating ElementReplace Solenoid Clean Solenoid ScreenRepair HOT Water Faucet Replace Timer AssemblyReplace HOT Water Faucet Coil Procedure Delime the Water Tank Servicing Instructions