TROUBLESHOOTING SUGGESTIONS

 

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

 

 

 

 

Water won't heat

Brewer unplugged or circuit

Check power supply cord

 

 

 

breaker tripped

Check / reset circuit breaker

 

 

 

 

 

 

 

 

Temperature setpoint too low

Set for desired temperature

 

 

 

 

 

 

 

 

Hi-Limit safety switch tripped

Allow to cool hi-limit will self-

 

 

 

 

 

 

reset

 

 

 

Damaged internal component or

Examine wiring & connectors,

 

 

 

wiring

thermostat and heating element

 

 

 

 

 

 

Repair/replace as needed

 

 

 

 

 

 

 

Coffee level too high or low

Timer out of adjustment

Adjust timer

 

 

 

 

 

 

 

Coffee level (only) too low

Plugged coffee solenoid strainer

Clean strainer

 

 

 

 

 

 

 

Tea level too high or low

Proper volume not selected

Set tea volume selector switch

 

 

 

 

 

 

to desired volume

 

 

 

 

 

 

 

Tea level (only) too low

Plugged tea solenoid strainer

Clean strainer

 

 

 

 

 

 

 

 

"TEA" not selected

Press COFFEE/TEA switch to

 

 

 

 

 

 

"TEA"

 

 

 

 

 

 

 

Brew chamber overflows

Too many filter papers or wrong

Use one (1) genuine Bloomfield

 

 

 

filter paper

filter per brew

 

 

 

Brew chamber dispense hole

Thoroughly clean brew

 

 

 

plugged

chamber

 

 

 

 

 

 

 

 

Wire rack not in place

Install proper wire rack

 

 

 

 

 

 

 

 

Too much coffee or too fine a

Use correct grind and amount

 

 

 

grind

of coffee

 

 

 

 

 

 

 

Sprays water from brew head

Spray gasket improperly

Check/reinstall gasket on

 

 

 

installed

INSIDE of brew head

 

 

 

Spray disk plugged

Clean spray disk

 

 

 

 

 

 

 

No brew (faucet flows OK)

Damaged internal component or

Check brew switch, wiring

 

 

 

wiring

& solenoid. Repair, replace as

 

 

 

 

 

 

needed

 

 

 

 

 

 

 

No dilution flow from bypass

"TEA" not selected

Press COFFEE/TEA switch to

 

 

nozzle

 

 

 

"TEA"

 

 

 

Damaged internal component or

Check wiring & tea bypass

 

 

 

wiring

solenoid. Repair, replace as

 

 

 

 

 

 

needed

 

 

 

 

 

 

 

No brew plus no flow from hot

Water supply OFF

Turn water supply ON

 

 

water faucet

 

 

 

 

 

 

 

Water filter (if used) plugged

Replace filter element

 

 

 

 

 

 

 

No flow from hot water faucet

Faucet valve turned OFF

Turn faucet valve ON

 

 

 

 

 

 

 

 

Faucet plugged

Disassemble faucet, clean

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M628 76201 Owners Manual 8781A Tea Brewer

Image 14
Contents 628 Warranty Statement Applicability Table of ContentsSpecifications Features and Operating Controls Precautions and General Information Agency Listing InformationLeveling the Unit InstallationPLUMBER’S Installation Instructions Installation ELECTRICIAN’S Installation InstructionsOperation Coffee START-UPOperational Notes POUR-OVER Option Automatic Operation TimerAutomatic Operation HOT Water FaucetBrewing Coffee PreparationBrewing TEA Tea Brew ChamberTools Cleaning InstructionsFrequency Troubleshooting Suggestions Symptom Possible Cause Suggested RemedySymptom Suggested Remedy TOP Panel Access PanelsServicing Instructions Front PanelTemperature Adjustment Elevation feet above seal levelReplace Thermostat Solenoid Time AdjustmentRemove Tank LID Assembly Replace Heating ElementReplace Solenoid Clean Solenoid ScreenReplace Timer Assembly Replace HOT Water Faucet CoilReplace Control Panel Light or Switch Repair HOT Water FaucetProcedure Delime the Water Tank Precautions8781A Exploded Views & Parts List 8781A Exploded Views & Parts List Tank LID Assembly 8781A Service KitsService Kits Faucet Repair Kits8781A Wiring Diagram Telephone Fax