SERVICING INSTRUCTIONS (continued)
REPLACE SOLENOID
Brewer
Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head.
Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Remove two screws holding access door in place. Remove two screws holding solenoid to door.
Remove brew water tube from solenoid. On faucet side, remove faucet water tube from bypass side of solenoid by pressing the white ring portion of the tube fitting tightly against the metal portion while pulling the tube off of the solenoid.
Disconnect wiring from solenoid.
Transfer solenoid bracket to new solenoid. Reassemble in reverse order.
CLEAN SOLENOID SCREEN
Symptom: Automatic brewer will not flow water.
Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Using
Reinsert screen in solenoid. Be careful to maintain correct orientation. (The OPEN END of the screen goes in FIRST.)
Fig. 13 Remove Faucet Supply from Solenoid
M628 76201 Owners Manual 8781A Tea
Reassemble in reverse order.
REPLACE TIMER ASSEMBLY
Unplug power cord or turn circuit breaker OFF.
Remove front panel. Remove knob and three screws holding timer to bracket. Disconnect wiring to timer.
Reassemble in reverse order.
Adjust timer as described on page 13
REPLACE HOT WATER FAUCET COIL
Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.
Remove tank lid assembly per above.
Remove two hex nuts hot water coil to cover. Pull coil from mounting holes.
Reassemble in reverse order.
17
Fig. 14 Clean Strainer Screen
IMPORTANT: When replacing water faucet coil, also replace seal gaskets.