Bloomfield 8781A owner manual Elevation feet above seal level, Temperature Adjustment

Page 17

SERVICING INSTRUCTIONS

TEMPERATURE ADJUSTMENT

Unplug power cord or turn circuit breaker OFF. Remove top panel.

Pull vent tube out of tank lid and insert a thermometer of known accuracy in hole. Reconnect brewer to electrical power.

Place empty container under brew chamber. Energize brewer and allow unit to heat. When the READY TO BREW light first glows, read the temperature displayed on thermometer.

Adjust thermostat by turning shaft; clockwise increases temperature. 1/8 turn = approximately 10ºF, or 5.6ºC.

Refer to Table 1 below for proper brewing temperature based on altitude.

Upon completion, remove thermometer and reinstall the vent line and top panel.

CAUTION

Electric Shock

Hazard

These procedures involve exposed electrical circuits. These procedures are to be performed by qualified technical personnel only.

NOTE: Optimum brewing temperature is 195ºF to 205ºF (90ºC to 96ºC).

Thermostat should be adjusted to a maximum temperature of 200ºF (95ºC).

IMPORTANT:

A mechanical thermostatwill maintain temperature within ±5ºF.

To prevent boiling water in the brewer, controller should be adjusted to a maximum temperature equal to the local boiling temperature minus 5ºF, or 200ºF (94ºC), whichever is

Owners Manual 8781A Tea Brewer

Fig. 10 Checking and Adjusting Brew Temperature

(ºF)

210

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

205

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

195

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

190

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

,500

,000

2,500

,000

 

4,000

 

00

000

 

00

 

00 ,500

 

0

500

,0

,500

4,5

5,5

6,0

 

 

 

 

 

1

1

2

3

3

 

5,

 

6

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELEVATION (feet above seal level)

BOILING

POINT OF WATER

IDEAL BREWING TEMPERATURE

MAXIMUM TEMPERATURE SETTING

less.

NOTE: 1/8 turn = approximately 10ºF (5.6ºC).

M628 76201

100

(ºC)

97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP.

94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

88

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

0

3

450 600

0

0

.0

0

 

0

.5

.6

.800 .950

 

 

 

75

90

 

.2

.350

 

 

5

00

 

 

 

5

 

0

1

00

1

50

1

 

 

 

 

 

 

 

 

 

1

 

1

 

1

 

 

1

 

 

 

 

ELEVATION (meters above seal level)

Table 1 Boiling Temperature by Altitude

15

BOILING

POINT OF WATER

IDEAL BREWING TEMPERATURE RANGE

MAXIMUM TEMPERATURE SETTING

Fig. 11 Adjust Thermostat

Image 17
Contents 628 Warranty Statement Applicability Table of ContentsSpecifications Features and Operating Controls Agency Listing Information Precautions and General InformationLeveling the Unit InstallationPLUMBER’S Installation Instructions ELECTRICIAN’S Installation Instructions InstallationOperation Coffee START-UPOperational Notes Automatic Operation Automatic Operation TimerPOUR-OVER Option HOT Water FaucetPreparation Brewing CoffeeTea Brew Chamber Brewing TEATools Cleaning InstructionsFrequency Symptom Possible Cause Suggested Remedy Troubleshooting SuggestionsSymptom Suggested Remedy Servicing Instructions Access PanelsTOP Panel Front PanelElevation feet above seal level Temperature AdjustmentRemove Tank LID Assembly Solenoid Time AdjustmentReplace Thermostat Replace Heating ElementReplace Timer Assembly Clean Solenoid ScreenReplace Solenoid Replace HOT Water Faucet CoilRepair HOT Water Faucet Replace Control Panel Light or SwitchPrecautions Procedure Delime the Water Tank8781A Exploded Views & Parts List 8781A Exploded Views & Parts List Service Kits 8781A Service KitsTank LID Assembly Faucet Repair Kits8781A Wiring Diagram Telephone Fax