Bloomfield 8781A owner manual Procedure Delime the Water Tank, Precautions

Page 21

SERVICING INSTRUCTIONS (continued)

M628 76201 Owners Manual 8781A Tea Brewer

PROCEDURE: Delime the Water Tank

PRECAUTIONS:

Disconnect brewer from electric power.

 

Allow brewer to cool.

FREQUENCY:

As required (Brewer slow to heat)

TOOLS:

Deliming Solution

 

Protective Gloves, Goggles & Apron

 

Mild Detergent, Clean Soft Cloth or Sponge

 

Bristle Brush, Bottle Brush

 

Large Sink (or other appropriate work area)

 

 

 

 

1.Unplug power cord. Turn off the water shut-off valve and disconnect the water supply line from the brewer inlet fitting.

2.Remove the tank lid assembly as described on page 13.

3.Remove the water tank from the brewer body by lifting straight up. Empty all water from the tank. Set the tank back into the brewer.

4.Mix 2 quarts of deliming solution according to the manufacturer’s directions. Carefully pour the deliming solution into the water tank. Lower the lid assembly back onto the tank. Allow to sit for 30 minutes, or as directed by the manufacturer.

5.At end of soaking period, remove lid assembly from tank. Thoroughly rinse internal components of lid assembly with clear water. Using a stiff bristle brush, scrub the heating element and faucet water coil to remove lime and calcium build-up. Rinse with clean water. Store lid assembly in a safe location.

6.Remove the tank from the brewer and empty. Using a stiff bristle brush, scrub the interior of the water tank to remove lime and calcium build-up. Rinse with clean water.

7.Set the tank back into the brewer. Reassemble the tank lid to the water tank. Make sure the gasket is properly in place, then reinstall lid clamps.

8.Reinstall wiring to heating element and thermostat. Reassemble piping for the faucet. Verify that all internal components are dry, then reinstall the top panel.

10.Reconnect brewer to electrical supply and reconnect water supply.

11.Install the brew chamber without filter paper or grounds. Run at least three full brew cycles and discard all water generated.

12.Brewer is ready to use.

CAUTION -

CHEMICAL BURN

HAZARD

Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure.

Never siphon deliming chemicals or solutions by

mouth.

This operation should only be performed by qualified and ex- perienced service personnel.

IMPORTANT: DO NOT spill, splash or pour water or deliming solution into or over any internal component other than the inside of the water tank.

IMPORTANT: DO NOT allow

any internal components to come into contact with the deliming solution. Take care to keep all internal components dry.

NOTE: Repeat steps 4 thru 5 as required to remove all scale and lime build-up.

NOTE: Normally, silicone hoses do not need to be delimed. Should deliming hoses become necessary, Bloomfield recommends replacing the hoses.

19

Image 21
Contents 628 Warranty Statement Table of Contents SpecificationsApplicability Features and Operating Controls Agency Listing Information Precautions and General InformationInstallation PLUMBER’S Installation InstructionsLeveling the Unit ELECTRICIAN’S Installation Instructions InstallationOperation START-UP Operational NotesCoffee Automatic Operation Automatic Operation TimerPOUR-OVER Option HOT Water FaucetPreparation Brewing CoffeeTea Brew Chamber Brewing TEACleaning Instructions FrequencyTools Symptom Possible Cause Suggested Remedy Troubleshooting SuggestionsSymptom Suggested Remedy Servicing Instructions Access PanelsTOP Panel Front PanelElevation feet above seal level Temperature AdjustmentRemove Tank LID Assembly Solenoid Time AdjustmentReplace Thermostat Replace Heating ElementReplace Timer Assembly Clean Solenoid ScreenReplace Solenoid Replace HOT Water Faucet CoilRepair HOT Water Faucet Replace Control Panel Light or SwitchPrecautions Procedure Delime the Water Tank8781A Exploded Views & Parts List 8781A Exploded Views & Parts List Service Kits 8781A Service KitsTank LID Assembly Faucet Repair Kits8781A Wiring Diagram Telephone Fax