Step 1. Position main power switch to “OFF”.
Step 2. Disconnect (unplug) water heater from
120 volt power source.
Step 3. Turnoff gas supply to water heater.
Step 4. Un-latch& remove surround cover from top of
heater.
Step 5. From thegas valve, disconnect
the gas connection, PVC venting,
wire harness and silicone tubing.
Step 6. Disconnect wire harness from
blower assembly.
Step 7. Removethe two screws holding
each the hot surface igniter and
flame sensor in place (long reach
magnetic Phillips screw driver).
Carefully remove hot surface igniter
and flame sensor from combustion
assembly. For Direct Spark Ignition models,
remove the two screws on the spark rod bracket
and remove the spark rod.
Step 8. Removethe 4 nuts (7/16" wrench) holding
the burner transition in place. Lift the blower/gas
valve transition assembly from burner mounting
insert, remove gasket andset aside.
Step 9. Removeburner tube from burner
mounting insert. See next page for
burner tube inspection procedure.
Burner Tube Removal Procedure
WARNING
120 volt potential exposure. Isolate the
appliance and reconfirm power is
disconnected using a multi-meter.
WARNING

Heater components may be HOT when performing the following steps in this procedure.

Take necessary precaution to prevent personal injury.

49
BURNER TRANSITION
MOUNTING NUTS
HOT
SURFACE
IGNITER/
SPARK ROD
49