BREWING COFFEE

CAUTION:

Burn Hazard

A. PREPARATION

Exposed surfaces of the brewer, brew chamber and decanter may be HOT to the touch, and can cause serious burns.

CAUTION:

Burn Hazard

To avoid splashing or overflowing hot liquids, ALWAYS place an empty decanter under the brew chamber before starting the brew cycle. Failure to comply can cause serious burns.

CAUTION:

Burn Hazard

After a brew cycle, brew chamber contents are HOT. Remove the brew chamber and dispose of used grounds with care.

Place one (1) genuine Bloomfield paper filter in the brew chamber.

Add a pre-measured amount of fresh coffee grounds. Gently shake the brew chamber to level the bed of grounds.

Slide the brew chamber into place under the brew head.

B. AUTOMATIC OPERATION

BE sure HEAT light is not lit.

Place the appropriate EMPTY decanter in place under the brew chamber.

Press the BREW switch. The BREW light will glow and a beep will sound.

The solenoid will open for an amount of time determined by the timer setting, admitting a measured quantity of water into the tank.

Fig. 10 Prepare Brew Chamber

Fig. 11 Press BREW to Start

Failure to comply can cause serious burns.

NOTE: The brewer will not initiate a second automatic brew cycle until the current cycle plus the drip-out time is completed. If the BREW key is pressed during this time, the BREW light will flash, indicating a brew in progress.

NOTE: Water for the hot water faucet is heated in a coil inside of the water tank. Use of the faucet will not affect the volume of water delivered for a brew. However, overuse of the faucet during a brew may lower the temperature of the brew water.

Inlet water will displace a like amount of heated water from the tank. The hot water will be forced into the brew head where it will spray over the bed of grounds. Freshly brewed coffee will begin to fill the container under the brew chamber.

At the end of the brew cycle, plus an amount of time set to allow all water to drip out of the brew chamber, three beeps will sound. When the flow and all dripping stops, the coffee is ready to serve.

Discard the contents of the brew chamber and rinse it in a sink. When the HEAT light goes out, the brewer is ready for another brew cycle.

C. WARMERS

At the start of a brew, the MAIN warmer is energized automatically. Press either the FRONT or REAR warmer switch to energize an auxiliary warmer. Set the filled decanter on the selected warmer to keep it warm.

10

641 75844 Owners Manual E.B.C. Decanter

Image 12
Contents Electronic Brew Control Warranty Statement Table of Contents SpecificationsApplicability Features and Operating Controls Precautions and General Information Agency Listing InformationElectrical Damage Burn HazardInstallation Instructions PLUMBER’S Installation InstructionsEquipment Hazard Leveling the UnitInstallation Instructions ELECTRICIAN’S Installation InstructionsOperation START-UPWater Heater Electronic Features Brew SettingsBrew Cancel Energizing the BrewerQuality Timer Disable/Enable After Hours FeatureOver-Temperature and Temperature Fault Protection After Hours OperationBrewing Coffee PreparationAutomatic Operation WarmersCleaning Instructions Electric Shock HazardTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyError Detection Electric Shock HazardWhat to Check Description Corrective Action Access Panels Servicing InstructionsTemperature Adjustment Servicing InstructionsBrew Time Adjustment Dripout Time AdjustmentRemove Tank LID Assembly Replace Temperature ProbeReplace Solenoid Replace Faucet Supply HoseReplace HOT Water Faucet Coil Repair HOT Water FaucetController Hook-Up Replace ControllerReplace Power Board SET Controller JumpersReplace Keypad Procedure Delime the Water Tank Servicing Instructions Exploded View & Parts List Exploded View & Parts List Exploded View & Parts List Bloomfield Paper Filter pk 1072 HOT Water Tank Assembly DescriptionElectrical Components Description Used onInternal Plumbing Components Wiring Diagram Wiring Diagram Wiring Diagram Telephone Fax

1072, 1040, 1012 specifications

Bloomfield 1040, 1012, and 1072 are three models that exemplify advanced technology and features in the realm of versatile machinery and equipment. Each model is tailored to meet specific operational needs while ensuring efficiency and performance.

The Bloomfield 1040 is renowned for its robust design and user-friendly interface. This model incorporates a powerful engine that guarantees high torque and speed, making it ideal for heavy-duty tasks. Its advanced control system allows for precise maneuverability, which is essential for applications in confined spaces. Additionally, the 1040 comes with a high-capacity fuel tank, ensuring prolonged operational time without the need for frequent refueling.

In terms of technology, the 1040 is equipped with state-of-the-art diagnostic capabilities. This feature enables users to monitor the machine's performance in real time, identifying potential issues before they escalate into costly repairs. The model also includes an intuitive digital display that provides vital information such as fuel levels, engine temperature, and maintenance reminders.

The Bloomfield 1012 model focuses on portability and ease of use. Weighing less than many competitors, the 1012 is designed for easy transport, making it perfect for landscaping, construction, and maintenance tasks. Its compact size does not compromise on power, as it features a high-efficiency engine that balances performance with fuel economy.

Moreover, the 1012 integrates wireless connectivity, allowing operators to control and monitor the machine remotely. This advancement significantly enhances productivity by streamlining operations and reducing downtime.

Lastly, the Bloomfield 1072 stands out with its innovative safety features. Equipped with multiple sensors and automated shut-off capabilities, this model prioritizes operator safety. The enhanced visibility offered by its design ensures that users maintain awareness of their surroundings while operating.

Furthermore, the 1072 includes built-in load monitoring systems that aid in preventing overload scenarios, prolonging the lifespan of the equipment.

In conclusion, Bloomfield 1040, 1012, and 1072 each bring unique features and enhancements to the table. Whether users prioritize power, portability, or safety, Bloomfield's commitment to quality and technological advancement ensures that operators will find a suitable solution within this lineup. These models not only enhance productivity but also promote efficiency, making them valuable assets in any operational context.