Bloomfield 1072, 1012, 1040 owner manual Electrical Components, Description Used on

Page 29

641 75844 Owners Manual E.B.C. Decanter

EXPLODED VIEW & PARTS LIST (continued)

ELECTRICAL COMPONENTS

ITEM

PART NO.

DESCRIPTION

USED ON

31

1012-10

Keypad

1012

 

1040-10

Keypad

1040

 

1072-10

Keypad

1072

35

8572-18

Element, 120V 100W

All

36

6407-15

Cord & Cap Assembly

1012, 1040

37

35-210

Strain Relief

1012, 1040

45

85753

Solenoid Valve, 120V

All

50

83644

Temperature Probe

All

63

8043-83

Hi-Limit Thermostat

1012, 1040, 1072

67

8043-14

Tank Heating Element 120V / 1500W

1012, 1040, 1072

85

1080-226

Controller Board

All

86

1080-40

Controller Dial

All

87

1072-225

Power Board

All

SOLENOID REPAIR KITS

 

 

85218

Inlet Fitting Kit (includes cap, fitting, gasket

 

 

 

and strainer)

 

 

85219

Inlet Strainer

 

27

Image 29
Contents Electronic Brew Control Warranty Statement Applicability Table of ContentsSpecifications Features and Operating Controls Agency Listing Information Precautions and General InformationElectrical Damage Burn HazardPLUMBER’S Installation Instructions Installation InstructionsEquipment Hazard Leveling the UnitELECTRICIAN’S Installation Instructions Installation InstructionsSTART-UP OperationWater Heater Brew Settings Electronic FeaturesBrew Cancel Energizing the BrewerDisable/Enable After Hours Feature Quality TimerOver-Temperature and Temperature Fault Protection After Hours OperationPreparation Brewing CoffeeAutomatic Operation WarmersElectric Shock Hazard Cleaning InstructionsSymptom Possible Cause Suggested Remedy Troubleshooting SuggestionsWhat to Check Description Corrective Action Error DetectionElectric Shock Hazard Servicing Instructions Access PanelsServicing Instructions Temperature AdjustmentDripout Time Adjustment Brew Time AdjustmentRemove Tank LID Assembly Replace Temperature ProbeReplace Faucet Supply Hose Replace SolenoidReplace HOT Water Faucet Coil Repair HOT Water FaucetReplace Controller Controller Hook-UpReplace Keypad Replace Power BoardSET Controller Jumpers Procedure Delime the Water Tank Servicing Instructions Exploded View & Parts List Exploded View & Parts List Exploded View & Parts List Bloomfield Paper Filter pk 1072 Description HOT Water Tank AssemblyDescription Used on Electrical ComponentsInternal Plumbing Components Wiring Diagram Wiring Diagram Wiring Diagram Telephone Fax

1072, 1040, 1012 specifications

Bloomfield 1040, 1012, and 1072 are three models that exemplify advanced technology and features in the realm of versatile machinery and equipment. Each model is tailored to meet specific operational needs while ensuring efficiency and performance.

The Bloomfield 1040 is renowned for its robust design and user-friendly interface. This model incorporates a powerful engine that guarantees high torque and speed, making it ideal for heavy-duty tasks. Its advanced control system allows for precise maneuverability, which is essential for applications in confined spaces. Additionally, the 1040 comes with a high-capacity fuel tank, ensuring prolonged operational time without the need for frequent refueling.

In terms of technology, the 1040 is equipped with state-of-the-art diagnostic capabilities. This feature enables users to monitor the machine's performance in real time, identifying potential issues before they escalate into costly repairs. The model also includes an intuitive digital display that provides vital information such as fuel levels, engine temperature, and maintenance reminders.

The Bloomfield 1012 model focuses on portability and ease of use. Weighing less than many competitors, the 1012 is designed for easy transport, making it perfect for landscaping, construction, and maintenance tasks. Its compact size does not compromise on power, as it features a high-efficiency engine that balances performance with fuel economy.

Moreover, the 1012 integrates wireless connectivity, allowing operators to control and monitor the machine remotely. This advancement significantly enhances productivity by streamlining operations and reducing downtime.

Lastly, the Bloomfield 1072 stands out with its innovative safety features. Equipped with multiple sensors and automated shut-off capabilities, this model prioritizes operator safety. The enhanced visibility offered by its design ensures that users maintain awareness of their surroundings while operating.

Furthermore, the 1072 includes built-in load monitoring systems that aid in preventing overload scenarios, prolonging the lifespan of the equipment.

In conclusion, Bloomfield 1040, 1012, and 1072 each bring unique features and enhancements to the table. Whether users prioritize power, portability, or safety, Bloomfield's commitment to quality and technological advancement ensures that operators will find a suitable solution within this lineup. These models not only enhance productivity but also promote efficiency, making them valuable assets in any operational context.