Bloomfield 1072, 1012, 1040 Troubleshooting Suggestions, Symptom Possible Cause Suggested Remedy

Page 14

 

 

TROUBLESHOOTING SUGGESTIONS

 

 

 

 

 

SYMPTOM

 

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water won’t heat

 

Brewer unplugged or circuit

Check power supply cord

 

 

 

 

(NOTE: Models 1016 & 1074

 

breaker tripped

Check / reset circuit breaker

 

 

 

 

must have power switch ON)

 

 

 

 

 

 

 

 

Temperature adjusted too low

Turn on and set for desired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or set to OFF

temperature. See page 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hi-Limit thermostat tripped

Allow to cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Damaged internal component or

Examine wiring & connectors,

 

 

 

 

 

 

 

wiring

controller, power board and

 

 

 

 

 

 

 

 

heating element

 

 

 

 

 

 

 

 

Repair/replace as needed

 

 

 

 

 

 

 

 

 

 

 

 

 

Coffee level too high or low

 

Timer out of adjustment

Adjust controller. See page 17

 

 

 

 

 

 

 

 

 

 

 

 

 

Brew chamber overflows

 

Too many filter papers or wrong

Use one (1) genuine Bloomfield

 

 

 

 

 

 

 

filter paper

filter per brew

 

 

 

 

 

 

 

Brew chamber dispense hole

Thoroughly clean brew chamber

 

 

 

 

 

 

 

plugged

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sprays water from brew head

 

Spray gasket improperly

Check/reinstall gasket on

 

 

 

 

 

 

 

installed

INSIDE of brew head

 

 

 

 

No brew while faucet flows OK

 

Spray disk plugged

Clean spray disk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Damaged internal component

Check keypad, controller, power

 

 

 

 

 

 

 

or wiring

board & solenoid

 

 

 

 

 

 

 

 

Repair, replace as needed

 

 

 

 

No brew plus no flow from hot

 

Water supply OFF

Turn water supply ON

 

 

 

 

water faucet

 

 

 

 

 

 

 

 

Solenoid screen plugged

Clean solenoid screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water line strainer (if used)

Clean strainer

 

 

 

 

 

 

 

plugged

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No flow from hot water faucet

 

Water filter (if used) plugged

Replace filter element

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Faucet valve turned OFF

Turn faucet valve ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Faucet plugged

Disassemble faucet, clean

 

 

 

 

 

 

 

 

 

 

 

 

 

Poor coffee quality

 

Keep brewer and decanters clean. Install a taste and odor filter in

 

 

 

 

 

 

 

water supply, and replace cartridges regularly.

 

 

 

 

 

 

 

Use a quality coffee with a consistent roast. Use proper grind and

 

 

 

 

 

 

 

amount of coffee per brew.

 

 

 

12

641 75844 Owners Manual E.B.C. Decanter

Image 14
Contents Electronic Brew Control Warranty Statement Applicability Table of ContentsSpecifications Features and Operating Controls Electrical Damage Precautions and General InformationAgency Listing Information Burn HazardEquipment Hazard Installation InstructionsPLUMBER’S Installation Instructions Leveling the UnitInstallation Instructions ELECTRICIAN’S Installation InstructionsOperation START-UPWater Heater Brew Cancel Electronic FeaturesBrew Settings Energizing the BrewerOver-Temperature and Temperature Fault Protection Quality TimerDisable/Enable After Hours Feature After Hours OperationAutomatic Operation Brewing CoffeePreparation WarmersCleaning Instructions Electric Shock HazardTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyWhat to Check Description Corrective Action Error DetectionElectric Shock Hazard Access Panels Servicing InstructionsTemperature Adjustment Servicing InstructionsRemove Tank LID Assembly Brew Time AdjustmentDripout Time Adjustment Replace Temperature ProbeReplace HOT Water Faucet Coil Replace SolenoidReplace Faucet Supply Hose Repair HOT Water FaucetController Hook-Up Replace ControllerReplace Keypad Replace Power BoardSET Controller Jumpers Procedure Delime the Water Tank Servicing Instructions Exploded View & Parts List Exploded View & Parts List Exploded View & Parts List Bloomfield Paper Filter pk 1072 HOT Water Tank Assembly DescriptionElectrical Components Description Used onInternal Plumbing Components Wiring Diagram Wiring Diagram Wiring Diagram Telephone Fax

1072, 1040, 1012 specifications

Bloomfield 1040, 1012, and 1072 are three models that exemplify advanced technology and features in the realm of versatile machinery and equipment. Each model is tailored to meet specific operational needs while ensuring efficiency and performance.

The Bloomfield 1040 is renowned for its robust design and user-friendly interface. This model incorporates a powerful engine that guarantees high torque and speed, making it ideal for heavy-duty tasks. Its advanced control system allows for precise maneuverability, which is essential for applications in confined spaces. Additionally, the 1040 comes with a high-capacity fuel tank, ensuring prolonged operational time without the need for frequent refueling.

In terms of technology, the 1040 is equipped with state-of-the-art diagnostic capabilities. This feature enables users to monitor the machine's performance in real time, identifying potential issues before they escalate into costly repairs. The model also includes an intuitive digital display that provides vital information such as fuel levels, engine temperature, and maintenance reminders.

The Bloomfield 1012 model focuses on portability and ease of use. Weighing less than many competitors, the 1012 is designed for easy transport, making it perfect for landscaping, construction, and maintenance tasks. Its compact size does not compromise on power, as it features a high-efficiency engine that balances performance with fuel economy.

Moreover, the 1012 integrates wireless connectivity, allowing operators to control and monitor the machine remotely. This advancement significantly enhances productivity by streamlining operations and reducing downtime.

Lastly, the Bloomfield 1072 stands out with its innovative safety features. Equipped with multiple sensors and automated shut-off capabilities, this model prioritizes operator safety. The enhanced visibility offered by its design ensures that users maintain awareness of their surroundings while operating.

Furthermore, the 1072 includes built-in load monitoring systems that aid in preventing overload scenarios, prolonging the lifespan of the equipment.

In conclusion, Bloomfield 1040, 1012, and 1072 each bring unique features and enhancements to the table. Whether users prioritize power, portability, or safety, Bloomfield's commitment to quality and technological advancement ensures that operators will find a suitable solution within this lineup. These models not only enhance productivity but also promote efficiency, making them valuable assets in any operational context.