Cecilware BC2-IT, BC301-IT, BC302-IT specifications Special Components Test and Adjustments

Page 18

SPECIAL COMPONENTS TEST AND ADJUSTMENTS

1) WATER INLET VALVE (SOLENOID) TEST (Located inside bottom cabin)

Turn power off from touchpad. If the water level rises inside the tank, and shoots out of the overflow, the Water Inlet Valve is leaking. Disconnect wires from the Water Inlet Valve coil and connect a 2 wire line cord to the terminals. Plug it into a 115V outlet. If water flows in and stops when you pull it out, the Valve is working fine. Repeat this test a few times. The problem may be in the Probe. If the water does not flow in when the cord is plugged into an electrical outlet, the Solenoid coil may be damaged, opened or the valve may have an obstruction preventing the water from flowing in. Clean or replace it.

A Check Valve is installed to prevent backflow.

To check proper function of Check Valve, disconnect water line from the Check Valve, check for dripping from the disconnected end of the Check Valve.

If it leaks replace it.

Water inlet Valve max. flow rate is 1.3 gal/min.

2) WATER LEVEL PROBE TEST (Located on tank top, inside top cabin)

If there is a lack of water, you will get an error message on the LCD window. Check the probe as follows:

Turn on the power from touchpad and water supply. Check inside the tank to make sure the water is not touching the Probe. Pull the wire and terminal out of the Probe rod. If water starts flowing into the tank, the Probe may be grounded, due to excessive liming. Check with Ohm meter. Clean or replace.

3) POWER SAFETY RELAY TEST (Located inside top cabin)

Turn power switch on from touchpad. Measure Voltage across Input to Coil, between terminals1& 2. Should read approx. 9V to 10V D.C.

Measure Voltage across Output, between terminals “COM” to Ground. Should read 120V. Measure Voltage across Input, between terminals “NO” to Ground. Should read 120V.

4)HEATER SAFETY RELAY TEST (Located inside top cabin) Make sure power switch in back of unit is on (toggle up).

Turn power switch on (energize) from touchpad. Measure Input Voltage across coil, between terminals 0 & 1. Should read 120V.

Measure Output Voltage across Heater Element. Should read 220 V. If there is no Voltage across the Heating Element, measure Output Voltage between terminals 4 & 8.

Turn power switch off from touchpad. The Voltage should be a constant 220V even when not energized.

Turn power switch on) from touchpad. Measure Voltage across terminals 2 & 6. Should read 220V.

If 120V was applied to relay coil and it does not energize, replace relay.

18

Image 18
Contents Single ModelsBC2-IT TwinSpecifications Electrical Specifications Mechanical SpecificationsSTART-UP Procedure Page Installation and Operating Instructions To Change Or Reset Parameter Values Programming InstructionsModes of Operation Overview Modes of Operation Descriptions Dilution Fill Constant Calibration State Brewing StateBrew Fill Constant Calibration State WarmersService Mode Infusion Time ## Seconds Dilution Delay ### SecondsWater Temperature Soak Time ## SecondsWarmer Power Lockout TemperatureSleep Timer ON/OFF Warmer Timer ON/OFFAdjust Seconds DAY HHMM## Weekend Timer ON/OFFClock Setup ON/OFF Adjust Minutes DAY HH##SSError Mode Parts Identification BC2-IT, BC302-IT Back ViewTOP Cabin Parts Identification Elbow TubeQTY BC2-IT Description To prepare a sanitizing solution Front View BC301-ITTroubleshooting Guide Problem Probable Cause RemedySpecial Components Test and Adjustments Power Safety Relay Test Located inside top cabinTo Adjust Water Flow Rate Cecilware Corporation 120/240V