Cecilware BC301-IT, BC2-IT, BC302-IT specifications To Adjust Water Flow Rate

Page 19

5) CHECK DISPENSE VALVES FOR LIME BUILD-UP (Located inside top cabin) Drain The Water Tank To Just Below The Level Of The Dispense Valves.

Remove The Valves And Clean. You Can Take These Valves Apart By Hand As Shown. Replace The Assembly As Needed.

Replace The Valve Into The Tank And Refill tank.

a) The SINGLE DISPENSE VALVE is factory adjusted to dispense 0.5 oz./sec. of water during the brew cycle (spray duration).

b) The DOUBLE/ DILUTION DISPENSE VALVE is factory adjusted, on both sides, to dispense 0.22 oz./sec of water during dilution cycle.

TO ADJUST WATER FLOW RATE:

Locate adjustment screw on valve (as show here).

Using an Allen Key or a flat screwdriver, rotate ¼ turn at a time,

Clockwise (CW) to decrease water flow rate or

Counter-Clockwise (CCW) to increase water flow rate.

Check water flow output after each ¼ turn.

19

Image 19
Contents Twin ModelsBC2-IT SingleMechanical Specifications Specifications Electrical SpecificationsSTART-UP Procedure Page Installation and Operating Instructions Programming Instructions To Change Or Reset Parameter ValuesModes of Operation Overview Modes of Operation Descriptions Warmers Brewing StateBrew Fill Constant Calibration State Dilution Fill Constant Calibration StateService Mode Soak Time ## Seconds Dilution Delay ### SecondsWater Temperature Infusion Time ## SecondsWarmer Timer ON/OFF Lockout TemperatureSleep Timer ON/OFF Warmer PowerAdjust Minutes DAY HH##SS Weekend Timer ON/OFFClock Setup ON/OFF Adjust Seconds DAY HHMM##Error Mode BC2-IT, BC302-IT Back View Parts IdentificationElbow Tube TOP Cabin Parts IdentificationQTY BC2-IT Description Front View BC301-IT To prepare a sanitizing solutionProblem Probable Cause Remedy Troubleshooting GuidePower Safety Relay Test Located inside top cabin Special Components Test and AdjustmentsTo Adjust Water Flow Rate Cecilware Corporation 120/240V