FRONT VIEW – BC301-IT

BACK VIEW – BC301-IT

 

CLEANING AND SANITIZING

SANITIZING:

All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first.

To prepare a sanitizing solution:

ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F). Note: Always start with a unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span.

Soak all parts for a minimum of 3 min. in the sanitizing solution.

Let all sanitized parts drain and dry naturally. DO NOT WIPE THEM DRY.

Before using the sanitized unit (or parts) with food stuffs, rinse all parts thoroughly with water.

Water pipe connecting and fixtures directly connected to a potable water supply shall be sized, installed, and maintained in accordance with Federal, Sate, and Local codes (section 7).

CLEANING:

1.Empty contents from brew funnel, wash and let dry (use a mild dishwasher detergent).

2.To wipe all surfaces of the machine, turn the power switch to OFF first, then wipe surfaces, then turn power back ON.

16

Image 16
Contents Models BC2-ITSingle TwinMechanical Specifications Specifications Electrical SpecificationsSTART-UP Procedure Page Installation and Operating Instructions Programming Instructions To Change Or Reset Parameter ValuesModes of Operation Overview Modes of Operation Descriptions Brewing State Brew Fill Constant Calibration StateDilution Fill Constant Calibration State WarmersService Mode Dilution Delay ### Seconds Water TemperatureInfusion Time ## Seconds Soak Time ## SecondsLockout Temperature Sleep Timer ON/OFFWarmer Power Warmer Timer ON/OFFWeekend Timer ON/OFF Clock Setup ON/OFFAdjust Seconds DAY HHMM## Adjust Minutes DAY HH##SSError Mode Parts Identification BC2-IT, BC302-IT Back ViewTOP Cabin Parts Identification Elbow TubeQTY BC2-IT Description To prepare a sanitizing solution Front View BC301-ITTroubleshooting Guide Problem Probable Cause RemedySpecial Components Test and Adjustments Power Safety Relay Test Located inside top cabinTo Adjust Water Flow Rate Cecilware Corporation 120/240V