Cecilware BC302-IT, BC2-IT, BC301-IT Programming Instructions, Modes of Operation Overview

Page 5

PROGRAMMING INSTRUCTIONS

TO ACCESS PROGRAMMING – Press Simultaneously Both Buttons

TO SCROLL THRU PROGRAMMING FUNCTIONS – Press One Button

TO CHANGE

OR RESET

PARAMETER

VALUES

 

LED

 

 

 

 

LIGHTS

 

 

 

 

 

 

 

microprocessor driven

CANCEL

LCD WINDOW

 

CANCEL

CAUTION

 

 

 

 

 

 

 

HOT WATER

 

POWER

 

 

 

BREW

WARMER

POWER

 

CANCEL LAST

BUTTONS

BUTTON

BUTTON

 

OPERATION

The following is a Functional Description of the Single Station Brewer:

Modes of Operation - Overview

Initialization Mode – This mode is only active during the first few seconds after a “power-on” or system reset. The main function of this mode is to perform some special self-testing functions and configure the system using the previously saved operating parameters.

Normal Mode – This mode becomes active immediately after Initializing Mode has completed its tasks. The main functions of this mode are to monitor and report system status and control brewing.

Service Mode – This mode becomes active when the hidden keys under the Cecilware Logo (located on the upper-left-hand side of the keypad) and the first letter of the Model Name (located on the upper-right- hand side of the keypad) are simultaneously depressed for more than two seconds while in Normal Mode.

The main function of this mode is to allow access (for qualified personnel) to all system parameters that can be modified.

Error Mode – This mode becomes active when the system detects a fatal error. The main function of this mode is to disable the unit and report the error to the operator.

5

Image 5
Contents BC2-IT ModelsSingle TwinSTART-UP Procedure Specifications Electrical SpecificationsMechanical Specifications Page Installation and Operating Instructions Modes of Operation Overview To Change Or Reset Parameter ValuesProgramming Instructions Modes of Operation Descriptions Brew Fill Constant Calibration State Brewing StateDilution Fill Constant Calibration State WarmersService Mode Water Temperature Dilution Delay ### SecondsInfusion Time ## Seconds Soak Time ## SecondsSleep Timer ON/OFF Lockout TemperatureWarmer Power Warmer Timer ON/OFFClock Setup ON/OFF Weekend Timer ON/OFFAdjust Seconds DAY HHMM## Adjust Minutes DAY HH##SSError Mode BC2-IT, BC302-IT Back View Parts IdentificationElbow Tube TOP Cabin Parts IdentificationQTY BC2-IT Description Front View BC301-IT To prepare a sanitizing solutionProblem Probable Cause Remedy Troubleshooting GuidePower Safety Relay Test Located inside top cabin Special Components Test and AdjustmentsTo Adjust Water Flow Rate Cecilware Corporation 120/240V