AEG 34942G installation instructions Instructions for the Installer, Engineers technical data

Page 12

Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS

Width:

860 mm.

 

Depth:

500 mm.

 

Height:

88 mm.

 

Weight:

8 Kg.

CUT OUT DIMENSIONS

Width:

830 mm.

 

Depth:

470 mm.

 

Thickness:

30 mm.

SUPPLY CONNECTIONS

Gas:

 

 

RC 1/2 inch (1/2 inch male) Rear right hand corner

 

Electric:

 

 

230-240V 50Hz supply, 3 core flexible cable with

 

non rewireable plug fitted with a 3 amp cartridge fuse.

IGNITION HT SPARK

Spark Generator

 

Ispra Control's BF 50066 - 230-240V 0.6 YA T120

 

Spark Gap : Fixed

HEAT INPUT

 

 

Rear Left Burner (semi rapid)

2.0 kW (6824 BTU/HR)

Front Left Burner (rapid)

 

3.0 kW Natural Gas (10236 BTU/HR)

 

 

2.8 kW L.P.G. (9554 BTU/HR)

Central Burner (double-crown)

3,5 kW (11942 BTU/HR)

Rear Right Burner (semi rapid)

2.0 kW (6824 BTU/HR)

Front Right Burner (auxiliary)

1.0 kW (3412 BTU/HR)

APPLIANCE CLASS

3

 

APPLIANCE CATEGORY

II2H3+

 

GAS SUPPLY

Natural gas G20 / 20mbar

12

Image 12
Contents 34942G/35940G/35941G/35944G Installation Child SafetyDuring Use Service Environmental InformationContents Guide to Use the instructions Description of the Hob Mod G Operation HOB BurnersMaintenance and Cleaning Hob TopPan Supports BurnersSymptom Solution Something Not Working?Service and Spare Parts 0870 5 929Guarantee Conditions European GuaranteeInstructions for the Installer Engineers technical dataBurner Important safety requirements LocationInstallation Gas Connection This book be ignoredCut Out Size BuildingBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop Place the sealingElectrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningConversion from Natural Gas to LPG Method