AEG 34942G installation instructions Burner

Page 13

 

 

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

DOUBLE

 

TYPE OF GAS

 

 

(large)

(medium)

(small)

CROWN

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

 

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

NATURAL GAS

POWER

kW

3.0

0.65

2.0

0.45

1.0

0.33

3.5

1.2

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

20 mbar

 

 

 

 

 

 

 

 

 

VALUE =

RATE

m3/h

0.286

0.057

0.190

0.038

0.095

0.028

0.333

0.114

 

37.78 MJ/m3

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

136

Adjust.

 

Ws - 50.7 MJ/ m3

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

LPG GAS

POWER

kW

2.8

0.65

2.0

0.45

1.0

0.33

3.5

1.2

 

28-30/37 mbar

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

 

 

 

RATE

g/h

202

43.5

144

29

72

21,5

252

86

 

49.92 MJ/Kg

 

 

 

 

 

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

86

40

71

32

50

28

93

56

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

Tap colour

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

Auxiliary

 

28

 

Red/Red

 

 

 

 

 

 

Semi-rapid

 

32

 

Blue/Blue

 

 

 

 

 

Rapid

 

40

 

Black/Black

 

 

 

 

 

Double-Crown

56

 

Black/Red

 

 

 

 

 

Aeration adjustment none

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

Image 13
Contents 34942G/35940G/35941G/35944G Child Safety InstallationDuring Use Environmental Information ServiceContents Guide to Use the instructions Description of the Hob Mod G HOB Burners OperationHob Top Maintenance and CleaningPan Supports BurnersSomething Not Working? Symptom Solution0870 5 929 Service and Spare PartsEuropean Guarantee Guarantee ConditionsEngineers technical data Instructions for the InstallerBurner Location Important safety requirementsInstallation This book be ignored Gas ConnectionBuilding Cut Out SizeBuilding over a cupboard or drawer Building over a kitchen unit with door Place the sealing Fitting the hob to the worktopThis HOB Must be Earthed Electrical connectionsPermanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Check gas supply at burner Ignition System / Gas IgnitionCommissioning Pressure TestingMethod Conversion from Natural Gas to LPG