AEG 34942G installation instructions Ignition System / Gas Ignition, Check gas supply at burner

Page 24

Fault finding

Ignition System / Gas Ignition

Ignitor does not spark

NO

YES

Check gas supply at burner

Check plug top fuse and replace if necessary

Check polarity and earth continuity of supply point

Check earth continuity of appliance

Light burner manually

Check by pass simmer adjusted

Check position of the electrode

Check fitting of burners

Check continuity from 'N' on the mains connector block and "O" on the ignitor unit

Check continuity from 'L' on the mains connector block and the taps ignition switches

Check continuity from the tip of each electrode to the terminals 1 to 5 on the ignitor unit

Check for breaks in the insulation of the HT leads

Check continuity from ignition switches connector to ignitor unit

Change the taps ignition switches

Change the ignitor unit

24

Image 24
Contents 34942G/35940G/35941G/35944G Installation Child SafetyDuring Use Service Environmental InformationContents Guide to Use the instructions Description of the Hob Mod G Operation HOB BurnersMaintenance and Cleaning Hob TopPan Supports BurnersSymptom Solution Something Not Working?Service and Spare Parts 0870 5 929Guarantee Conditions European GuaranteeInstructions for the Installer Engineers technical dataBurner Important safety requirements LocationInstallation Gas Connection This book be ignoredCut Out Size BuildingBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop Place the sealingElectrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningConversion from Natural Gas to LPG Method