-Remove three cover plates by removing two screws from each plate. See Figure 15.3.
Remove
Plates
Figure 15.3 Remove Three Plates
-Remove three outside burner tubes by removing two screws on each tube. See Figure 15.4.
Figure 15.4 Remove Outside Burner Tubes
-Outside burner tube air shutters may be adjusted as shown in Figure 15.5.
Figure 15.5 Outside Burner Tube Air Shutter Adjustment
•Center Burner Tube Air Shutter
-Remove decorative steel log assembly by removing 3 screws, lifting up and out (Figure 15.6).
Figure 15.6 Remove Decorative Steel Log Assembly
-Center burner tube air shutter is now accessible with short phillips screw driver (see Figure 15.7).
Figure 15.7 Adjust Center Burner Tube Air Shutter
-Loosen phillips screw and turn air shutter for optimum flame appearance.