B. Additional Decorative Finishing up to 1 in. (25 mm) Thick

If an additional decorative facing is to be used (i.e. tile, marble) the front edge of the appliance must be 1/2 in. (13 mm) plus the thickness of the facing material (up to

1 in./25 mm thick) past the edge of the framing to achieve a flush fit with the SSF-LUX-BK Surround Kit. See Figure 14.3.

C. Additional Decorative Finishing over 1 in. (25 mm) Thick

If the additional decorative facing is to be used is over

1 in./25 mm thick (i.e. rock, brick, etc.) the front edge of the appliance must be 1/2 in. (12 mm) past the edge of the framing. The LUX60-TMPLT Rock Template must be used to allow air flow through the SSF-LUX60 Surround Kit. See Figure 14.4.

Sheetrock

1/2 in. Cement Board

Air Flow

Wood Framing

Steel Stud Assy

Use the instructions included with the template for instal- lation.

WARNING! Risk of Fire! DO NOT restrict the 1 in. air gap with any facing material!

Sheetrock Wood Framing

1/2 in. (13 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Cement Board

 

 

 

 

Steel Stud Assy

 

 

 

 

Top Rock

 

 

 

 

 

 

Template

 

 

 

 

 

 

 

 

Air Flow

 

 

 

 

 

 

 

 

 

1 in. (25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

air gap

 

 

 

 

 

 

 

1 1/2 in. MAXIMUM

Figure 14.3 1/2 in. Sheetrock plus Wall Finishing to 1 in.

SSF-LUX-BK

(shown for

reference only)

1/2 in. (13 mm)

Figure 14.4 1/2 in. Sheetrock plus Wall Finishing over 1 in.

48

Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11

Page 48
Image 48
Heat & Glo LifeStyle LUX60 owner manual Additional Decorative Finishing up to 1 in mm Thick