Heat & Glo LifeStyle LUX60 A. IntelliFire IPI Ignition System continued, Symptom, Possible Cause

Models: LUX60

1 60
Download 60 pages 44.77 Kb
Page 53
Image 53

A. IntelliFire (IPI) Ignition System (continued)

Symptom

Possible Cause

Corrective Action

4. Pilot lights but continues

A. A shorted or loose connection

Verify all connections to wiring diagram in manual. Verify

to spark, and main burner

in flame sensing rod.

connections underneath pilot assembly are tight. Verify

will not ignite. (If the pilot

 

connections are not grounding out to metal chassis, pilot burner,

continues to spark after

 

pilot enclosure or screen if present, or any other metal object.

the pilot flame has been lit,

 

 

flame rectification has not

 

 

B. Poor flame rectification or

With fixed glass assembly in place, verify that flame is engulfing

occurred.)

contaminated flame sensing

flame sensing rod on left side of pilot hood. Flame sensing rod

 

 

rod.

should glow shortly after ignition. Verify correct pilot orifice is

 

 

installed and gas inlet is set to pressure specifications.

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

Verify that wire harness is firmly connected to the module.

 

 

 

 

D. Damaged pilot assembly or

Verify that ceramic insulator around the flame sensing rod is not

 

contaminated flame sensing

cracked, damaged, or loose. Verify connection from flame sensing

 

rod.

rod to white sensor wire. Clean flame sensing rod with emery

 

 

cloth to remove any contaminants that may have accumulated on

 

 

flame sensing rod. Verify continuity with a multimeter with ohms

 

 

set at lowest range. Replace pilot if any damage is detected.

 

 

 

 

E. Module.

Deactivate the fireplace with the POWER button of the remote.

 

 

Remove ignitor wire “I” from module. Reactivate the fireplace

 

 

with the POWER button of the remote. If there is no spark at

 

 

“I” terminal module must be replaced. If there is a spark at “I”

 

 

terminal, module is fine.

 

 

 