Heat & Glo LifeStyle LUX60 owner manual C. Install the Ceiling Firestop

Models: LUX60

1 60
Download 60 pages 44.77 Kb
Page 32
Image 32
C. Install the Ceiling Firestop

C. Install the Ceiling Firestop

A ceiling firestop MUST be used between floors and at- tics.

Frame an opening 10 in. by 10 in. (254 mm by 254

mm)whenever the vent penetrates a ceiling/floor (see Figure 8.3).

Frame the area with the same sized lumber as used in ceiling/floor joist.

The ceiling firestop may be installed above or below the ceiling joists when installed with a attic insulation shield. It must be under joists between floors that are not insulated. Refer to Figure 8.4.

Secure with three fasteners on each side.

WARNING! Risk of Fire! DO NOT pack insulation around the vent. Insulation must be kept back from the pipe to pre- vent overheating.

Attic Above

Manual background 10 in. (254 mm)

Manual background 10 in. (254 mm)

Hole should measure

10 in. x 10 in.

(254 mm x 254 mm)

inside to inside

Figure 8.3 Installing Ceiling Firestop

Install attic insula- tion shields before or after installation

of vent system.

3 fasteners Manual backgroundManual background per side Manual backgroundManual backgroundManual background

 

 

 

 

 

 

 

Ceiling

 

firestop

Ceiling

 

firestop

 

 

installed below ceiling.

installed above ceiling.

Figure 8.4 Installing the Attic Shield

 

 

 

32

Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11

Page 32
Image 32
Heat & Glo LifeStyle LUX60 owner manual C. Install the Ceiling Firestop