TROUBLESHOOTING

 

Table 5-5. C204 PSB/PSE Board Component Repair 3/3

 

 

Symptom

Cause

Checkpoint

 

Solution

The 5 VDC line is

IC204 is defective.

Check the voltage level at pin 10 (V1)

 

Replace IC204.

defective.

 

and pin5 (GP).

 

 

 

 

Observe the drive waveform at pin 8

 

Replace IC204 or

 

 

(VO) and pin 5 (GP).

 

ZD211.

37 VDC line

IC102 is defective. (If

When the input voltage of the minus

 

Replace IC203.

(VP1/VP2) is

this IC is defective, it

port (pin 6 for VP1 and pin2 for VP2) is

 

 

abnormal.

cannot monitor the 37

less than 1.3 VDC, the comparator

 

 

 

VDC lines, and

outputs a HIGH signal.

 

 

 

printing operation

 

 

 

 

becomes abnormal.),

 

 

 

37 VDC line (VP3)

IC203 is defective. (If

When the input voltage of the plus port

 

Replace IC203.

is abnormal.

this IC is defective, it

is bigger than 1.3 VDC, the comparator

 

 

 

cannot monitor the 37

outputs a HIGH signal.

 

 

 

VDC lines, and motor

 

 

 

 

operations become

 

 

 

 

abnormal.),

 

 

 

 

 

 

Rev. B

5-15

Page 189
Image 189
Epson DFX-8500 service manual Troubleshooting