DISASSEMBLY AND ASSEMBLY

3.2.6.4 Ribbon Jam Sensor Removal

Step 1: Remove the right cover. (Refer to Section 3.2.3.2)

Step 2: Disconnect the connector for the sensor from the connector junction board.

Step 3: Remove the CP(S-P1) (M3x6) screw securing the sensor to the bracket, and remove the sensor.

C P ( S - P 1 ) ( M 3

F r o n t / R e a r T r a c t o r S e le c t L e v e r A s

Figure 3-51. Ribbon Jam Sensor Removal

Rev. B

3-35

Page 125
Image 125
Epson DFX-8500 service manual Ribbon Jam Sensor Removal