DFX-8500

P l a t e n

 

 

T e n s io n G a u g e

1 3 5

-

1 6 5

T h ic k n e s s G a u g e

 

( B E T A 3 ' = 0 . 4 3 m m )

 

Figure 4-19. Thickness Gauge Setting Method

Table 4-1. BETA Values Adjustment

Beta No.

Reference Thickness Gauge

Allowed Value

Default Value*1)

BETA 3'

0.43 mm with 150gf pull

 

-

-

BETA 2

0.00 mm

367

- 419

408

BETA 3

0.43 mm

405

- 437

435

BETA 4

0.80 mm

418

- 475

461

*1: When EEPROM is reset.