DFX-8500

3.2.4.6 AC Inlet Removal

Step 1: Remove the C204 power supply board assembly. (Refer to Section 3.2.4.2)

Step 2: Remove the C204 MAIN board assembly. (Refer to Section 3.2.4.5)

Step 3: Remove the three CBB (M3x8) screws and one CB (O) (M4x6) screw securing the grounding plate to the bottom panel assembly and remove the grounding plate.

C B B ( M 3 XB8o)t t o m P a n e l A s s e m b l

G r o u n d in g P la

C B ( O )

( M 4 X 6 )

A C I n le t S e t

Figure 3-35. Grounding Plate Removal

Step 4: Remove the two CFS (M3x10) screws securing the AC inlet to the grounding plate and remove the AC inlet.

A C I n le t S e t

G r o u n d in g

P la t e

C F S ( M 3 X 1 0 )

Figure 3-36. AC Inlet Removal

3-26

Rev. B

Page 116
Image 116
Epson DFX-8500 service manual AC Inlet Removal, Grounding Plate Removal