DISASSEMBLY AND ASSEMBLY

Step 5: Remove the four CBB (M3x12) screws and two CBS (O) (M3x8) screws securing the C204 MAIN board unit and remove the board.

:

C B S ( O ) ( M 3 X 8 ) X 2

:

C B B ( M 3 X 1 2 ) X 4

 

C 2 0 4 M A I N B o a r d U n

H o o k s f o r C 2 0 4 M A I N

Figure 3-34.C204 MAIN Board Removal 4/4

ADJUSTMENT REQUIRED

When you install the C204 MAIN board assembly, perform the following adjustments:

z￿ Platen gap motor value (platen gap) adjustment (described in Section 4.1.7).

z￿ Bidirectional printing adjustment (described in Section 4.1.8).

 

 

 

Rev. B

3-25

Page 115
Image 115
Epson DFX-8500 service manual 34.C204 Main Board Removal 4/4