Bosch Appliances 6805, TRUE, 6806, 4306, 4302, 6802 manual Diagram, SHI/U 43- Models

Page 74

72

 

 

H

Diagram 1

 

 

 

 

 

 

 

 

 

 

 

FUNCTION

DURATION

 

COMMENTS

 

 

 

 

 

 

 

DRAINING

30 Seconds

 

 

 

 

 

 

 

 

 

 

AQUA SENSOR CALIBRATION

65 Seconds

 

Not used on the SHI/U 43--

 

 

 

 

 

 

 

FILLING

Until Water Level Switch (f1)

 

This function cannot be bypassed

 

 

Closes.

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING &

Until Water Temperature Reaches

 

Dispenser Actuator Energizes

 

 

CIRCULATING

150° f.

 

 

 

 

 

 

 

 

 

 

 

 

DRAINING

60 Seconds

 

 

 

 

 

 

 

 

 

 

• To bypass a function: SHI/U 43--

Press the SCRUB WASH button

 

 

 

SHI/U 53--/68-- Press the REGULAR WASH button.

SHI/U 43— MODELS

To begin the test program, press the POWER SCRUB PLUS and REGULAR WASH buttons both in at the same time as you turn the unit on by pressing the ON/OFF button. When released the LED’s for the two programs will begin flashing.

To check all LED indicator lamps press the SCRUB WASH button.

To start the test program, press the POWER SCRUB PLUS and REGULAR WASH buttons both in a second time.

When the test program is complete, if a fault is detected the following indicator LED’s will be illuminated.

WASH

=

Heating Fault

RINSE/DRY

=

Filling Fault

CLEAN

=

NTC Fault

SHU 53— or SHI/U 68— MODELS

To begin the test program, press the SCRUB WASH and DELICATE/ECONO buttons both in at the same time as you turn the unit on by pressing the ON/OFF button. The version number of the circuit board will appear in the display, 20, 21, etc.

When released the LED’s for the two programs will begin flashing.

The check each LED press the corresponding program button. To check the countdown display and refill rinse aid LED press the REGULAR WASH button.

To start the test program, press the SCRUB WASH and DELICATE/ECONO buttons both in a second time.

When the test program is complete, the countdown display will indicate a fault or combination of faults using the following codes. If a combination of faults exists, the code numbers are added together. (6 = faults 2 + 4).

0 = No Faults

1 = Aqua Sensor Fault

2 = Heating Fault

4 = Filling Fault

8 = NTC Fault

Image 74
Contents Bosch Introduction Table of Contents SHV Service Reminder DescriptionSHI Section Warranty / Technical Specifications Customer Service Technical ServiceModel / Serial Number Location Product Overview NTCProduct Overview Page Section Operation Cycle Chart 24.75 20.25To Cancel a Cycle To OperateType of dishware China Pots/pans SHU 5302/5304/5305/5306/5312/5314/5315/5316 3.8 2.5 26.9/18.9 22.7/15.9 20.4/14.4 13.5/9.5 0.8 3.2 7Fig Power Scrub Regular Delicate Page Section Rack System Rack System Interior Features Interior Features Water Level Interior Features Detergent / Rinse-Agent Dispenser Drying Washability / DryingWashability HOW this System FunctionsService Reminder Outer Door Removal Door Components Dispenser Operation Outer Door Removal Door Compoments Dispenser Operation To Remove To InstallDispenser Removal Facia Assembly Removal Facia AssemblyImportant Service Note Control Unit Removal ON/OFF Switch RemovalDoor Latch Assembly Removal Page Section Base Components Front Accessible = 7 8 2 9 =Base Components Front Accessible Base Components Front Accessible Cut Away View Service Reminder Section Left Side Access Left Side Panel RemovalLeft Side Components Water Inlet / Discharge System Operation Draining FillingCode Water Inlet / Discharge System Removal Section Right Side Access Right Side Panel RemovalRight Side Components Component ExplanationNTC Operation NTC Removal NTC Removal NTC Removal NTC Removal NTC is held in place by two locking tabs, items 1 Page Section Tank Removal Tank Removal Tank Removal Base Components Circulation Pump / Motor Removal Circulation Pump / Motor Assembly Circulation Pump / Motor RemovalHeater Assembly Removal Heater Assembly Heater Assembly RemovalAqua Sensor Door Spring Removal To Replace the SpringsPage Section Diagram SHI/U 43- ModelsDiagram Timer u Power Scrub Flow Switch Circulation Motor Economy BKBU-f4 BU-l6-4 GY-l6-1 BNBK-b-3 Economy NTC Control Unit l2 Ground PE Wiring Connectors I5 Control Unit Reed Switch e3 185˚F On/Off Switch a1 Door Switch e0 BSH Home Appliances