SECTION 3
OPERATION
II.COMPONENT INFORMATION AND LOCATION (Figures 3-1 and 3-2)
A. Door Safety Switch
The Door Safety Switch is located at the lower right side of control panel opening. Opening the control panel door permits this switch to open, disconnecting power to all electrical controls, except for the blower motor inverters, located in the left side control cabinet.
CAUTION
Do NOT touch the wires going to this safety switch. Current is always present.
B. Blower Switch
The blower switch has two positions. The switch must be “ON” or “I” for the main blowers to come on and permit the oven to run. The fan circulates the air throughout the oven and must stay on during baking and during the cool down cycle above 200°F (93°C) to prevent blower
bearing damage. To protect the blower motor and bearings a thermostatic override is built into the oven. If the temperature inside the oven is over 200°F (93°C) the main blower will continue to run after the blower switch is turned to the “OFF” or “O” position.
C. Heat / Conveyor Switch
The “Heat/Conveyor Switch” allows the heat to come on. Activation is determined by the settings on the Digital Temperature Controller.
D. Temperature Controller
The temperature controller is a
The temperature controller contains a
#ONVEYOR 0OWER 4RANSFORMER | #OOLINGL&AN |
4EMPERATUREU
#ONTROL
#ONVEYOR 3PEED
#ONTROLT"OARD
#IRCUITC"REAKERS
3WITCH
(EAT#ONVEYOR
3WITCH
(I,O"LOWER 3PEEDE2ELAY
#ONVEYOR | (IGH ,IMIT | (IGH ,IMIT | $ISC |
'EARMOTOR | 4HERMOSTAT | 2ESET | 4HERMOSTAT |
Figure 3-2. Interior View of Control Console
16