Temp. display inoperative

Display Transformer

Measure the transformer primary for a nominal 120

 

 

VAC input, if voltage is not present, trace wiring back

 

 

to the oven power source. Measure the secondary

 

 

output, which will normally be 12-15 VAC. Voltage

 

 

across terminals 1 and 3 on the time/temp. display

 

 

should read 12-15 VAC. Terminals 1-2 and 2-3

 

 

should be 1/2 the voltage reading to 1-3. If the

 

 

above secondary readings are not achieved, replace

 

 

transformer.

 

Temp. Display

If proper voltage is present at terminals 1, 2, and 3

 

 

on temperature display, but the display is not lighted,

 

 

recheck all connections for tightness. If temperature

 

 

display is still not operating, replace the temperature

 

 

display.

Temp. Display inaccurate,

Thermocouple

Place the thermocouple of a pyrometer into the

erratic or inoperative

 

center of the top finger. Be sure the tip of the

 

 

thermocouple is not touching metal, it must sense air

 

 

temperature only. The pyrometer will indicate oven

 

 

temperature. Measure DC millivolts of thermocouple

 

 

at the temperature display. See thermocouple chart

 

 

on page 19 for proper readings. Replace

 

 

thermocouple if proper readings are not achieved. If

 

 

readings are correct on the thermocouple, replace

 

 

temperature display.

12

Impinger II – Advantage Service Manual - Domestic

Image 12
Contents Impinger Conveyor Ovens Table of Contents Sequence of Operations Impinger II AdvantageControl BOX Auto Cool Down Heater CircuitSchematic 1116-000-A, 1117-000-A Schematic 1130-000-A / 1131-000-A Schematic 1132-000-A / 1133-000-A Troubleshooting Guide / GAS Ovens PhaseNatural GAS LP GASPage With Power on and Thermocouple Leads Attached to the Temperature ControlPage Page Troubleshooting Guide / Electric Ovens Single PhaseThree Phase Refer to Proper Schematic for Identified ComponentsWith Power on and Thermocouple Leads Attached to the TemperaturePage Page REMOVAL, INSTALLATION, and Adjustment ON/OFF Switch ReplacementMOTOR, Main FAN FAN, MainFuse Holder Replacement THERMOSTAT, Control BOX HI-LIMIT ReplacementBurner Blower Motor Replacement High Limit Thermostat ReplacementBurner Transformer Replacement Thermocouple ReplacementThermocouple Measurement Chart InformationElectronic Temperature Control Board Replacement Electronic Temperature Control Board CalibrationTemperature Control Potentiometer Replacement Heat Light ReplacementTemperature Regulation Valve Replacement HOT Surface Ignitor ReplacementMain Burner Orifice Replacement Conveyor Control Potentiometer ReplacementConveyor Control Board Replacement Conveyor Drive Motor ReplacementConveyor Control Board Calibration Circuit BreakerHall Effect Sensor Replacement Temperature Display Transformer ReplacementTemperature Display Replacement Calibration of Temperature DisplayHeating Element Replacement BEARING, ConveyorThis page intentionally left blank Parts / General Letter Part Number DescriptionBlow UP / General Parts / Control BOX 1116-000-A, 1117-000-A Blow UP / Control BOX 1116-000-A, 1117-000-A Parts / Control BOX 1130-000-A Thru 1133-000-A Blow UP / Control BOX 1130-000-A Thru 1133-000-A Parts / Conveyor & Door Blow UP / Conveyor & Door Parts / Oven Back Assembly Blow UP / Oven Back Assembly