Page 16

 

Hall Effect Sensor

Check for any physical damage to hall effect sensor

 

 

(mounted on conveyor drive motor.) Check all

 

 

wiring and connections for damage. check all

 

 

connections for damage. Check all connections for

 

 

tightness or proper location and check all wiring for

 

 

visible damage. Replace as needed . Connect

 

 

new hall effect to system and check for steady

 

 

operation.

Temp. Display inoperative

Display Transformer

Measure the transformer primary for input, if

 

 

voltage is not present, trace wiring back to the oven

 

 

power source. Measure the secondary output,

 

 

which will normally by 12-15 VAC. Voltage across

 

 

terminals 1 and 3 on the time/temp. display should

 

 

read 12-15 VAC. Terminals 1-2 and 2-3 should be

 

 

1/2 the voltage reading from 1-3. if the above

 

 

secondary readings are not achieved, replace

 

 

transformer

 

Temperature Display

If proper voltage is present at terminals 1, 2, and 3

 

 

on temperature display, but the display is not

 

 

lighted, recheck all connections for tightness.

 

 

Temperature display is still not operating, replace

 

 

the temperature display.

Temp. Display inaccurate,

Thermocouple

Place the thermocouple of a pyrometer into the

erratic or inoperative

 

center of the top finger. Be sure the tip of the

 

 

thermocouple is not touching metal, it must sense

 

 

air temperature only. The pyrometer will indicate

 

 

oven temperature.

 

 

Measure DC millivolts of thermocouple at the

 

 

temperature display. See thermocouple chart on

 

 

page 19 for proper readings. Replace

 

 

thermocouple if proper readings are not achieved.

 

 

If readings are correct on the thermocouple, replace

 

 

temperature display.

16

Impinger II – Advantage Service Manual - Domestic

Image 16
Contents Impinger Conveyor Ovens Table of Contents Sequence of Operations Impinger II AdvantageControl BOX Auto Cool Down Heater CircuitSchematic 1116-000-A, 1117-000-A Schematic 1130-000-A / 1131-000-A Schematic 1132-000-A / 1133-000-A Troubleshooting Guide / GAS Ovens PhaseNatural GAS LP GASPage With Power on and Thermocouple Leads Attached to the Temperature ControlPage Page Troubleshooting Guide / Electric Ovens Single Phase Three Phase Refer to Proper Schematic for Identified ComponentsWith Power on and Thermocouple Leads Attached to the TemperaturePage Page REMOVAL, INSTALLATION, and Adjustment ON/OFF Switch ReplacementMOTOR, Main FAN FAN, MainFuse Holder Replacement THERMOSTAT, Control BOX HI-LIMIT ReplacementBurner Blower Motor Replacement High Limit Thermostat ReplacementBurner Transformer Replacement Thermocouple ReplacementThermocouple Measurement Chart InformationElectronic Temperature Control Board Replacement Electronic Temperature Control Board CalibrationTemperature Control Potentiometer Replacement Heat Light ReplacementTemperature Regulation Valve Replacement HOT Surface Ignitor ReplacementMain Burner Orifice Replacement Conveyor Control Potentiometer ReplacementConveyor Control Board Replacement Conveyor Drive Motor ReplacementConveyor Control Board Calibration Circuit BreakerHall Effect Sensor Replacement Temperature Display Transformer ReplacementTemperature Display Replacement Calibration of Temperature DisplayHeating Element Replacement BEARING, ConveyorThis page intentionally left blank Parts / General Letter Part Number DescriptionBlow UP / General Parts / Control BOX 1116-000-A, 1117-000-A Blow UP / Control BOX 1116-000-A, 1117-000-A Parts / Control BOX 1130-000-A Thru 1133-000-A Blow UP / Control BOX 1130-000-A Thru 1133-000-A Parts / Conveyor & Door Blow UP / Conveyor & Door Parts / Oven Back Assembly Blow UP / Oven Back Assembly