CONTACT TOASTER TROUBLESHOOTING GUIDE
PROBLEM | CAUSE | SOLUTION | ||
Buns won’t toast.... | a. | Wrong temperature setting. | a. | Set Thermostat at 4000 or number 8 and allow a full |
| b. | Wrong oil is used. | b. | 20 minutes for |
| Coconut oil is the recommended oil. Use of other | |||
| c. | Improper application of oil. | c. | oils will prove to be unsatisfactory. |
| Sun surface should have even application of oil. | |||
| d. | Excessive cupping of bread | d. | Use fresher bread. Get better cutting from baker. |
|
| surface. |
|
|
Buns toast unevenly. . . . | a. | Only part of bun surface is | a. | Improper application of oil - brush bun over butter |
|
| toasted - other part is pale in |
| roll so as to provide bun surface with even coating |
| b. | color and dry. | b. | of oil. |
| Excessive cupping of bread | Use fresher bread. Get better cutting from baker. | ||
| c. | surface. | c. | Adjust conveyor hanging brackets. |
| Not enough pressure. | |||
Buns stick to grill | a. | Wrong oil is used. | a. | Review Operation Information, Paragraph A, "Use of |
| b. | Grill surface has | b. | Oil" |
| Clean grill surface. Use | |||
|
| residue. |
| through residue. Daily cleaning will prevent residue |
| c. | Doughy buns or excess sugar | c. | |
| Set temperature to 4100 or number 8 and, perhaps, | |||
|
| and moisture plus overheated |
| use |
| d. | grill may cause sticking. | d. | Use sandpaper to roughen the surface of the |
| Bun weights on conveyor chain | |||
|
| assembly are too slick and |
| weight. |
| e. | slide off the bun. | e. | Defrost buns. |
| Buns not defrosted | |||
| f. | For c, d, and e above. | f. | Use Teflon sheet. |
Unit Dead - No power. . | a. | No power at wall receptacle. | a. | Check fuse of breaker panel. |
| b. | Plug disconnected. | b. | Check plug. |
| c. | Relay | c. | Check the relay output |
| d. | Main Switch. | d. | Check that switch is on and operative. |
| e. | Circuit Breaker. | e. | Check and reset. |
Grill won't heat | ......and conveyor and butter roller |
|
| |
| a. | are OKAY | a. | Check power cord connection in control panel. |
| Loose power cord connections. | |||
| b. | Loose control connections. | b. | Check control. |
| c. | Faulty thermostat | c. | Replace thermostat. |
| d. | Burnt out element. | d. | Replace element. |
Conveyor and Butter Roller | ......and grill OKAY | a. | Check switch for loose or broken connections. | |
Inoperative | a. | Loose connections to switch. | ||
| b. | Switch burned out. | b. | Replace switch. |
| c. | Motors defective. | c. | Replace motors. |
Butter Roller won't turn . | ......and butter roller motor OKAY | a. | Realign butter roll shaft to engage with drive. | |
| a. | Notched end of butter roll shaft | ||
| b. | not engaged with motor drive. | b. | Reverse butter roll and shaft assembly notched end |
| ||||
|
| in spring loaded socket. |
| toward motor drive. |
Conveyor won't move. . . | ......and conveyor motor OKAY |
|
| |
| ......and butter roller OKAY | a. | Remove conveyor and | |
| a. | Drive gears not engaged. | ||
| b. | Bun weights are binding. | b. | gears engaged properly. |
| Check weights for clearance between each one. | |||
| c. | Linkage is binding - and | c. | Check conveyor linkage for bent links. |
|
| conveyor drive motor won't turn. |
|
|
Conveyor won't move. . . | a. | Loose connection between | a. | Check circuit switch to conveyor motor for loose or |
| b. | switch and conveyor motor. | b. | broken connection. |
| Conveyor motor burnt out. | Replace motor. |
9