Bunn HC-3 service manual Frother and Whipper Motor, Whipper Motor Terminals

Page 21

SERVICE (cont.)

FROTHER AND WHIPPER MOTOR (cont.)

4.Remove dispense tip (3) and twist the whipper chamber (4) clockwise and pull it off the whipper chamber receptacle (8).

5.Pull the frother (6) off the motor shaft. Notice the flat side on the shaft and the matching flat inside the frother. It is important that these two flats are lined up when reassembling.

6.Slip the o-ring (5) off the whipper chamber receptical (8).

7.Remove the two #6-32 screws (7) securing whip- per chamber receptical (8) to the front panel.

8.Slide the receptical w/seal off of the motor shaft.

9.Slide teflon washer (9) and o-ring (10) off of the motor shaft.

10.Disconnect the black leads on the motor (12) from the main wiring harness.

11.Remove the two #8-32 acorn nuts (11) securing the motor (12) to the rear of front panel.

12.Remove motor and discard. See NOTE.

13.Install new motor (12) on rear of front panel and secure with two #8-32 acorn nuts (11) and con- nect black leads on the motor to the main wiring harness.

14.Slide o-ring (10) onto the motor shaft to approxi- mately 1/8” of the front panel.

15.Wash remaining components in a mild solution of dish detergent using a bristle brush.

16.Rinse thoroughly and allow to dry before reinstall- ing in the dispenser.

17.Place teflon washer into back opening of whipper chamber receptical and align one notch with bump in the opening.

18.Slide whipper chamber receptacle w/seal on to the motor shaft and secure to the front panel using two #6-32 screws (7).

19.Slip o-ring (5) onto the whipper chamber receptical

(8).

20.Push frother (6) onto the motor shaft, making sure the flat in the frother (6) lines up with the flat on the motor shaft.

21.Install whipper chamber (4) on the whipper cham- ber receptical (8) by twisting counterclockwise until the tabs on the whipper chamber (4) lock with the tabs on the whipper chamber receptical (8). Be sure dispense port is pointing down.

22.Install dispense tip (3) into the bottom of the

whipper chamber (4). Be sure the cutout part of the dispense tip is facing the outside of the dis- penser.

23.Slip the mixing chamber (2) onto the mixing chamber water inlet tube far enough so the mixing chamber (2) will seat inside the whipper chamber

(4).

24.Install the steam collector (1) onto the mixing chamber (2) by pushing down and toward the dispenser while twisting until the flange on the steam collector lines-up with the slot in the front panel.

25.Refer to illustration below when reconnecting the wires.

NOTE: To remove the center motor you also have to remove the hopper assy., fan and exhaust tube. Refer to AUGER DRIVE COMPONENTS and FAN.

P1207.50

FIG.13 WHIPPER MOTOR TERMINALS

21

27591 031597

 

Image 21
Contents Serial # HC00025000 UP Bunn HC-2Introduction WarrantyUser Notices 12368.000227620.0000 Electrical Requirements Initial SET-UPElectrical HOOK-UP Plumbing RequirementsAdjustments CleaningDispenser USE Cold Beverage SET-UP OptionalTroubleshooting Draining the HOT Water TankHopper Dispense Rate of Product Problem Probable Cause Remedy TroubleshootingProblem Dripping from dispense tip Lime build-up Problem Probable CauseOn stainless steel surfaces can Ing in serious leaksTesting procedure. See Weak product Water temperature30 or Tip with a thermometerProbable Cause Remedy Troubleshooting ProblemComponent Access ServiceContents Auger Drive ComponentsIf voltage is present as described, proceed to #5 Auger Drive ComponentsWasher Auger Motor Locknut Dust Seal Shoulder Screw Hopper AssyRight HC-2 ServiceTest Procedure BallastLocation Control Thermostat Remove temperature probe from the tankLocation Mechanical Thermostat Electronic Thermostat OptionalThermostat Terminals Control ThermostatDispense Switch Dispense SwitchFAN Test ProceduresSteam Collector #6-32 Screw Mixing Chamber Frother and Whipper MotorRing Pull the mixing chamber 2 out of the whipper chamberWhipper Motor Terminals Frother and Whipper MotorReconnect the eight pin connector to the hopper delay board Hopper Delay BoardDisconnect the wires from the switch termi- nals HOT/COLD Switch OptionalLamp Replacement Refer to Fig Lamp HolderDoor Assy Service Level Control Board and Probe Level Control Board and Level ProbeLimit Thermostat Level Board TerminalsOverflow Protection Switch Overflow Protection SwitchRUN/RINSE Switch RUN/RINSE SwitchCold Water Solenoid Valve Solenoid Valve Cold Water OptionalSolenoid Valves Dispense Cold Water Solenoid TerminalsSolenoid Valves Dispense Disconnect the water line from the solenoid valveSolenoid Valve Inlet Tank Heater Solenoid Valve InletRefer to when reconnecting the wires to the tank heater Tank Heater SwitchTank Heater Tank Heater Switch Terminals Tank Heater SwitchMODELSONLYcont Transformer 240V TWO WireSchematic Wiring Diagram HC-2, & HC-3 Schematic Wiring Diagram HCA-2, & HCA-3