Bunn HC-3 service manual Level Board Terminals, Limit Thermostat

Page 27

SERVICE (cont.)

LEVEL CONTROL BOARD AND LEVEL PROBE (cont.)

If voltage is present as described, reinstall the probe, the level control board and level probe are operating properly.

If voltage is not present as described, check the pink probe wire for continuity.

Removal and Replacement:

1.Remove all wires from the level control board.

2.Remove two #8-32 keps nuts holding level control board to upper left rear of the front panel.

3.Remove level control board and spacers.

3.Install the new level control board and spacers to the upper left rear of the front panel using two #8- 32 keps nuts.

4.Refer to the illustration below when reconnecting the wires.

Location:

The limit thermostat is located in the center of the tank lid.

Test Procedures:

1.Disconnect the dispenser from the power source.

2.Disconnect both black wires from the limit ther- mostat.

3.Check for continuity across the limit thermostat terminals.

If continuity is present as described, the limit thermo- stat is operating properly.

If continuity is not present as described, replace the limit thermostat.

Removal and Replacement:

1.Remove all wires from the limit thermostat ter- minals.

2.Carefully slide the limit thermostat out from un- der the retaining clip and remove the limit ther- mostat.

3.Carefully slide the new limit thermostat into the retaining clip.

4.Refer to the illustration below when reconnect- ing the wires.

BLK to Control

 

 

BLK to Tank

Thermostat

 

 

 

Heater

FIG. 18 LEVEL BOARD TERMINALS

LIMIT THERMOSTAT

P1210

FIG. 19 LIMIT THERMOSTAT

P1199.45

27

 

P1800

FIG. 20 LIMIT THERMOSTAT TERMINALS

27591 061500

Image 27
Contents Serial # HC00025000 UP Bunn HC-2Introduction WarrantyUser Notices 12368.000227620.0000 Plumbing Requirements Initial SET-UPElectrical Requirements Electrical HOOK-UPCold Beverage SET-UP Optional CleaningAdjustments Dispenser USETroubleshooting Draining the HOT Water TankHopper Dispense Rate of Product Problem Probable Cause Remedy TroubleshootingProblem Ing in serious leaks Problem Probable CauseDripping from dispense tip Lime build-up On stainless steel surfaces canTip with a thermometer Weak product Water temperatureTesting procedure. See 30 orProbable Cause Remedy Troubleshooting ProblemAuger Drive Components ServiceComponent Access ContentsHopper Assy Auger Drive ComponentsIf voltage is present as described, proceed to #5 Washer Auger Motor Locknut Dust Seal Shoulder ScrewRight HC-2 ServiceTest Procedure BallastLocation Electronic Thermostat Optional Remove temperature probe from the tankControl Thermostat Location Mechanical ThermostatThermostat Terminals Control ThermostatDispense Switch Dispense SwitchFAN Test ProceduresPull the mixing chamber 2 out of the whipper chamber Frother and Whipper MotorSteam Collector #6-32 Screw Mixing Chamber RingWhipper Motor Terminals Frother and Whipper MotorReconnect the eight pin connector to the hopper delay board Hopper Delay BoardDisconnect the wires from the switch termi- nals HOT/COLD Switch OptionalLamp Replacement Refer to Fig Lamp HolderDoor Assy Service Level Control Board and Probe Level Control Board and Level ProbeLimit Thermostat Level Board TerminalsOverflow Protection Switch Overflow Protection SwitchRUN/RINSE Switch RUN/RINSE SwitchCold Water Solenoid Valve Solenoid Valve Cold Water OptionalSolenoid Valves Dispense Cold Water Solenoid TerminalsSolenoid Valves Dispense Disconnect the water line from the solenoid valveSolenoid Valve Inlet Tank Heater Solenoid Valve InletRefer to when reconnecting the wires to the tank heater Tank Heater SwitchTank Heater Tank Heater Switch Terminals Tank Heater SwitchMODELSONLYcont Transformer 240V TWO WireSchematic Wiring Diagram HC-2, & HC-3 Schematic Wiring Diagram HCA-2, & HCA-3