Bunn HC-3 service manual Cold Water Solenoid Terminals, Solenoid Valves Dispense

Page 31

SERVICE (cont.)

SOLENOID VALVE (COLD WATER - OPTIONAL) (cont.)

WHI/YEL to Hot/Cold

Switch

WHI to Terminal Block

P1215

FIG. 26 COLD WATER SOLENOID TERMINALS

SOLENOID VALVES (DISPENSE)

FIG. 27 DISPENSE SOLENOID VALVES P1203.45

Location:

The dispense solenoids are located on the upper right side of the tank.

Test Procedures:

1.Disconnect the dispenser from the power source.

2.Disconnect the white and white/violet, white/blue or white/ brown wires from the solenoid valve. With the “RUN/RINSE” switch in the "RINSE" upper position press the appropriate dispense switch on front of the door.

3.Check the voltage across the white and white/ violet, white/blue or white/brown wires with a voltmeter. Connect the dispenser to the power source. The indication must be 120 volts ac for two wire 120 volt models, three wire 120/208, 120/240 volt models and 240 volts ac for two wire 240 volt models.

4.Disconnect the dispenser from the power source,

If voltage is present as described, proceed to #5

If voltage is not present as described, refer to wiring diagram and check dispenser wiring harness.

5.Check for continuity across the solenoid valve coil terminals.

If continuity is present as described, reconnect the white and white/violet, white/blue or white/brown wires to the solenoid.

If continuity is not present as described, replace the solenoid valve.

6.Check the solenoid valve for coil action. Connect the dispenser to the power source. With "RUN/ RINSE" switch in the "RINSE" upper position press the appropriate dispense switch and listen care- fully in the vicinity of the solenoid valve for a "click- ing" sound as the coil magnet attracts.

7.Disconnect the dispenser from the power source.

If the sound is heard as described and water will not pass through the solenoid valve, there may be a block- age in the water outlet before the solenoid valve or, the solenoid valve may require inspection for wear, and removal of waterborne particles.

If the sound is not heard as described, replace the solenoid valve.

Removal and Replacement:

1.Remove the white and white/violet, white/blue or white/ brown wires from the solenoid valve.

2.Turn-off the water supply to the dispenser.

31

27591 031597

 

Image 31
Contents Serial # HC00025000 UP Bunn HC-2Introduction Warranty12368.0002 User Notices27620.0000 Plumbing Requirements Initial SET-UPElectrical Requirements Electrical HOOK-UPCold Beverage SET-UP Optional CleaningAdjustments Dispenser USEDraining the HOT Water Tank TroubleshootingHopper Dispense Rate of Product Problem Probable Cause Remedy TroubleshootingProblem Ing in serious leaks Problem Probable CauseDripping from dispense tip Lime build-up On stainless steel surfaces canTip with a thermometer Weak product Water temperatureTesting procedure. See 30 orProbable Cause Remedy Troubleshooting ProblemAuger Drive Components ServiceComponent Access ContentsHopper Assy Auger Drive ComponentsIf voltage is present as described, proceed to #5 Washer Auger Motor Locknut Dust Seal Shoulder ScrewRight HC-2 ServiceBallast Test ProcedureLocation Electronic Thermostat Optional Remove temperature probe from the tankControl Thermostat Location Mechanical ThermostatThermostat Terminals Control ThermostatDispense Switch Dispense SwitchFAN Test ProceduresPull the mixing chamber 2 out of the whipper chamber Frother and Whipper MotorSteam Collector #6-32 Screw Mixing Chamber RingWhipper Motor Terminals Frother and Whipper MotorReconnect the eight pin connector to the hopper delay board Hopper Delay BoardDisconnect the wires from the switch termi- nals HOT/COLD Switch OptionalLamp Holder Lamp Replacement Refer to FigDoor Assy Service Level Control Board and Probe Level Control Board and Level ProbeLimit Thermostat Level Board TerminalsOverflow Protection Switch Overflow Protection SwitchRUN/RINSE Switch RUN/RINSE SwitchCold Water Solenoid Valve Solenoid Valve Cold Water OptionalSolenoid Valves Dispense Cold Water Solenoid TerminalsDisconnect the water line from the solenoid valve Solenoid Valves DispenseSolenoid Valve Inlet Tank Heater Solenoid Valve InletTank Heater Switch Refer to when reconnecting the wires to the tank heaterTank Heater Tank Heater Switch Terminals Tank Heater SwitchMODELSONLYcont Transformer 240V TWO WireSchematic Wiring Diagram HC-2, & HC-3 Schematic Wiring Diagram HCA-2, & HCA-3