SERVICE (cont.)
SOLENOID VALVES (DISPENSE) (cont.)
3.Drain enough water from the tank so the water level is below the dispense valve mounting hole.
NOTE:
4.Disconnect the water line from the solenoid valve.
5.Remove the
6.Using the
7.Push the water line onto the tube on bottom of solenoid valve.
8.Refer to Fig. 26 when reconnecting the wires.
FIG. 26 DISPENSE SOLENOID VALVE | P1216 |
| |
TERMINALS |
|
SOLENOID VALVE (INLET)
FIG. 27 INLET SOLENOID VALVE | P1203.45 |
| |
Location: |
|
The inlet solenoid is located on the lower right side of the rear panel.
Test Procedures:
1.Disconnect the dispenser from the power source.
2.Disconnect the white and violet wires from the solenoid valve.
3.Check the voltage across the white and violet wires with a voltmeter. Connect the dispenser to the power source. The indication must be 120 volts ac for two wire 120 volt models, three wire 120/208, 120/240 volt models and 240 volts ac for two wire 240 volt models.
4.Disconnect the dispenser from the power source,
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to the wiring diagram and check dispenser wiring harness.
5.Check for continuity across the solenoid valve coil terminals.
If continuity is present as described, reconnect the white and violet wires to the solenoid.
32 | 27591 031597 |
|